Zink and sodium high pressure lamps for curing composite resins
Andrej Meniga
; Faculty of Dentistry of the University of Zagreb, Croatia
Jozo Šutalo
; Faculty of Dentistry of the University of Zagreb, Croatia
Jadranka Rukavina
; Factory of Electric Lamps (TEŽ), Zagreb, Croatia
Davorka Azinović
; Institute of Physics of the University of Zagreb, Croatia
Goran Pichler
; Institute of Physics of the University of Zagreb, Croatia
APA 6th Edition Meniga, A., Šutalo, J., Rukavina, J., Azinović, D. i Pichler, G. (1990). Zink and sodium high pressure lamps for curing composite resins. Acta stomatologica Croatica, 24 (4), 233-240. Preuzeto s https://hrcak.srce.hr/101162
MLA 8th Edition Meniga, Andrej, et al. "Zink and sodium high pressure lamps for curing composite resins." Acta stomatologica Croatica, vol. 24, br. 4, 1990, str. 233-240. https://hrcak.srce.hr/101162. Citirano 21.04.2021.
Chicago 17th Edition Meniga, Andrej, Jozo Šutalo, Jadranka Rukavina, Davorka Azinović i Goran Pichler. "Zink and sodium high pressure lamps for curing composite resins." Acta stomatologica Croatica 24, br. 4 (1990): 233-240. https://hrcak.srce.hr/101162
Harvard Meniga, A., et al. (1990). 'Zink and sodium high pressure lamps for curing composite resins', Acta stomatologica Croatica, 24(4), str. 233-240. Preuzeto s: https://hrcak.srce.hr/101162 (Datum pristupa: 21.04.2021.)
Vancouver Meniga A, Šutalo J, Rukavina J, Azinović D, Pichler G. Zink and sodium high pressure lamps for curing composite resins. Acta stomatologica Croatica [Internet]. 1990 [pristupljeno 21.04.2021.];24(4):233-240. Dostupno na: https://hrcak.srce.hr/101162
IEEE A. Meniga, J. Šutalo, J. Rukavina, D. Azinović i G. Pichler, "Zink and sodium high pressure lamps for curing composite resins", Acta stomatologica Croatica, vol.24, br. 4, str. 233-240, 1990. [Online]. Dostupno na: https://hrcak.srce.hr/101162. [Citirano: 21.04.2021.]
Sažetak Polimerisation caracteristics of conventional units for curing composite resins are insufficient considering handling feasibilities particularly in the premolar and molar region. There is also hazardous ocular effect of near ultra-violet part of visible spectra. Sodium high pressure lamp tehnology has been applied to develop a new high pressure zinc lamp, which is for the first time used for curing composite materials. The results of polymerisation measurements show that future improvements over the
usual halogen light sources are possible. Zinc lamp was also compared with the high pressure sodium lamp filled with mercury or cadmium.