Građevinar, Vol. 66 No. 03., 2014.
Prethodno priopćenje
Evaluation of brick resistance to freeze / thaw cycles according to indirect procedures
Ivanka Netinger
; Sveučilište J.J. Strossmayera u Osijeku, Građevinski fakultet Osijek
Martina Vračević
; Institut građevinarstva Hrvatske, PC Osijek
Janja Ranogajec
; Sveučilište u Novom Sadu, Tehnološki fakultet
Snežana Vučetić
; Sveučilište u Novom Sadu, Tehnološki fakultet
Sažetak
The brick resistance was tested in the paper by direct method, and according to some indirect procedures presented in international literature and regulations. Requirements for indirect estimation of brick resistance to freeze / thaw cycles set by Canadian and U.S. standards have proven to be inapplicable, and the same applies to estimation based on pore structure. A connection between absorption/ desorption of water and brick resistance to freeze/thaw cycles was observed.
Ključne riječi
resistance to freeze/thaw cycles; compressive strength; boiling absorption; water absorption; saturation coefficient; pore structure; absorption/desorption of water
Hrčak ID:
119897
URI
Datum izdavanja:
10.4.2014.
Posjeta: 2.962 *