Skoči na glavni sadržaj

Prethodno priopćenje

Influence of Prepared Cavity Surface on Microleakage - Pilot Study

Alena Knežević
Marija Ujević
Višnja Negovetić-Mandić
Vlatko Pandurić
Jozo Šutalo


Puni tekst: hrvatski pdf 198 Kb

str. 47-51

preuzimanja: 1.003

citiraj

Puni tekst: engleski pdf 60 Kb

str. 53-56

preuzimanja: 721

citiraj


Sažetak

Enamel and dentin are, by their very chemical structure, two different substrates which necessitate different preparation before placing of composite resin. The aim of this study was to show how various enamel and dental pretreatment methods (“total etch” technique and self etching adhesives) affect the quality of bonding with composite resin. The results obtained showed optimal etching time, using 37% orthophospohoric acid, of 20 seconds for enamel and 10 seconds for dentin.

Ključne riječi

etching; self etching adhesives; microleakage

Hrčak ID:

1378

URI

https://hrcak.srce.hr/1378

Datum izdavanja:

15.3.2004.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.437 *