EXPERIMENTAL DESIGN APPLIED TO MODELING OF THE AIR-TIGHTNESS OF A BUILDING

Ivana Miličević ; Josip Juraj Strossmayer University of Osijek, Faculty of Civil Engineering Osijek
Irena Ištoka Otković ; Josip Juraj Strossmayer University of Osijek, Faculty of Civil Engineering Osijek
Željko Koški ; Josip Juraj Strossmayer University of Osijek, Faculty of Civil Engineering Osijek


Puni tekst: engleski pdf 348 Kb

str. 41-46

preuzimanja: 574

citiraj


Sažetak

The paper presents experimental designs that can be used in modeling of the air-tightness of buildings as second-order functions using response surface method and corresponding experiment designs. The factors supposed to be significant for a model of building air-tightness—and thus those used in experiment designs—are the heat transfer coefficient for external walls, the heat transfer coefficient of the windows, and the position of the housing units with respect to the building envelope. We compared three-level full factorial and fractional factorial designs, as well as central composite designs and the Box–Behnken design.

Ključne riječi

air-tightness; design of experiment; factorial designs; central composite designs; Box–Behnken design