Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.20471/acc.2017.56.03.08

Measurable and Unmeasurable Features of Ultrasound Lymph Node Images in Detection of Malignant Infiltration

Tatjana Rotim orcid id orcid.org/0000-0003-0866-0129 ; Department of Diagnostic and Interventional Radiology, Osijek, Croatia
Branka Kristek ; Department of Diagnostic and Interventional Radiology, Osijek, Croatia
Tajana Turk orcid id orcid.org/0000-0003-1535-1359 ; Department of Diagnostic and Interventional Radiology, Osijek, Croatia
Domagoj Kretić orcid id orcid.org/0000-0003-0279-0651 ; Department of Diagnostic and Interventional Radiology, Osijek, Croatia
Marija Perić ; Department of Clinical Cytology, Osijek University Hospital Center, Osijek, Croatia
Ivo Pušeljić ; Department of Diagnostic and Interventional Radiology, Osijek, Croatia
Tijana Pandurović orcid id orcid.org/0000-0002-6670-804X ; Department of Diagnostic and Interventional Radiology, Osijek, Croatia
Mario Štefanić ; 3Department of Nuclear Medicine and Oncology, School of Medicine, Josip Juraj Strossmayer University of Osijek, Osijek, Croatia


Puni tekst: engleski pdf 113 Kb

str. 415-424

preuzimanja: 1.010

citiraj


Sažetak

The aim of the study was to assess diagnostic value and utility of selected morphological features in predicting lymph node (LN) malignancy using B-mode, Doppler ultrasonography and multivariate settings in a tertiary radiological referral center. The study included 123 patients having undergone ultrasound-guided fine-needle aspiration and cytologic analysis (FNAC) of cervical, axillary and inguinal LNs. Each LN was characterized by long/L and short/T-axis, shape, margins, echogenicity, cortical thickness, vascularization, and examiner’s subjective impression. Within the limitations of FNAC, altered shape and vascularization had relatively high specificity and positive predictive value (>80%), whereas subjective impression had high sensitivity and negative predictive value (100%) for malignancy. The cut-off levels for different features of LN by ROC analysis were as follows: long-axis 23 mm, short-axis 11 mm, L/T ratio 2.19, and maximal cortical thickness 5.1 mm. On multivariate analysis (adaptive regression splines, n=108), the addition of long-axis, L/T ratio, age and sex considerably improved diagnostic accuracy (88%), sensitivity (margins + vascularization) and specificity (subjective impression) of the diagnostic model. The combination of morphological and demographic features could improve diagnostic accuracy, usually with a trade-off between the sensitivity and specificity of the predictive model. The performance may depend on the level of expertise and institutional settings.

Ključne riječi

Lymph nodes – abnormalities; Ultrasonography, doppler; Biopsy, fine-needle; Cytodiagnosis; Predictive value of tests; Croatia

Hrčak ID:

191369

URI

https://hrcak.srce.hr/191369

Datum izdavanja:

1.9.2017.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.385 *