Skoči na glavni sadržaj

Izvorni znanstveni članak

Criticality Safety Analysis of Spent Fuel Storage Pool for NPP Mochovce using MCNP5 Code

Ján Haščík ; Slovak University of Technology, Faculty of Electrical Engineering and Information Technology, Institute of Nuclear and Physical Engineering, Ilkovicova 3, 812 19 Bratislava, Slovakia
Gabriel Farkas ; Slovak University of Technology, Faculty of Electrical Engineering and Information Technology, Institute of Nuclear and Physical Engineering, Ilkovicova 3, 812 19 Bratislava, Slovakia
Jakub Lüley ; Slovak University of Technology, Faculty of Electrical Engineering and Information Technology, Institute of Nuclear and Physical Engineering, Ilkovicova 3, 812 19 Bratislava, Slovakia
Branislav Vrban ; Slovak University of Technology, Faculty of Electrical Engineering and Information Technology, Institute of Nuclear and Physical Engineering, Ilkovicova 3, 812 19 Bratislava, Slovakia
Róbert Hinca ; Slovak University of Technology, Faculty of Electrical Engineering and Information Technology, Institute of Nuclear and Physical Engineering, Ilkovicova 3, 812 19 Bratislava, Slovakia
Martin Petriska ; Slovak University of Technology, Faculty of Electrical Engineering and Information Technology, Institute of Nuclear and Physical Engineering, Ilkovicova 3, 812 19 Bratislava, Slovakia
Vladimír Slugeň ; Slovak University of Technology, Faculty of Electrical Engineering and Information Technology, Institute of Nuclear and Physical Engineering, Ilkovicova 3, 812 19 Bratislava, Slovakia
Jozef Lipka ; Slovak University of Technology, Faculty of Electrical Engineering and Information Technology, Institute of Nuclear and Physical Engineering, Ilkovicova 3, 812 19 Bratislava, Slovakia


Puni tekst: engleski pdf 897 Kb

preuzimanja: 229

citiraj


Sažetak

The paper presents results of nuclear criticality safety analysis of spent fuel storage and
handling for the 1st and 2nd unit of NPP Mochovce. Spent fuel storage pool (compact and reserve
grid) and T-12 transport cask were modeled using the Monte Carlo code MCNP5. Conservative
approach was applied and calculation of max
eff k values was performed for normal and various
postulated emergency conditions in order to evaluate the final maximal max
eff k values. The
requirement of current safety regulations to ensure 5% subcriticality was met except some
especially conservative cases.

Ključne riječi

sub criticality; spent fuel storage; safety regulation

Hrčak ID:

199054

URI

https://hrcak.srce.hr/199054

Datum izdavanja:

31.7.2017.

Posjeta: 679 *