hrcak mascot   Srce   HID

Tehnički vjesnik, Vol. 25 No. 6, 2018.

Prethodno priopćenje
https://doi.org/10.17559/TV-20170329230603

Selecting the Size of the Universal Reducer, Taking into Account its Thermal Load Capacity

Milan Rackov   ORCID icon orcid.org/0000-0003-4956-5849 ; Faculty of Technical Sciences, University of Novi Sad, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia
Siniša Kuzmanović ; Faculty of Technical Sciences, University of Novi Sad, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia
Zoran Anišić ; Faculty of Technical Sciences, University of Novi Sad, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia

Puni tekst: engleski, pdf (1 MB) str. 1829-1836 preuzimanja: 59* citiraj
APA 6th Edition
Rackov, M., Kuzmanović, S. i Anišić, Z. (2018). Selecting the Size of the Universal Reducer, Taking into Account its Thermal Load Capacity. Tehnički vjesnik, 25 (6), 1829-1836. https://doi.org/10.17559/TV-20170329230603
MLA 8th Edition
Rackov, Milan, et al. "Selecting the Size of the Universal Reducer, Taking into Account its Thermal Load Capacity." Tehnički vjesnik, vol. 25, br. 6, 2018, str. 1829-1836. https://doi.org/10.17559/TV-20170329230603. Citirano 27.05.2019.
Chicago 17th Edition
Rackov, Milan, Siniša Kuzmanović i Zoran Anišić. "Selecting the Size of the Universal Reducer, Taking into Account its Thermal Load Capacity." Tehnički vjesnik 25, br. 6 (2018): 1829-1836. https://doi.org/10.17559/TV-20170329230603
Harvard
Rackov, M., Kuzmanović, S., i Anišić, Z. (2018). 'Selecting the Size of the Universal Reducer, Taking into Account its Thermal Load Capacity', Tehnički vjesnik, 25(6), str. 1829-1836. doi: https://doi.org/10.17559/TV-20170329230603
Vancouver
Rackov M, Kuzmanović S, Anišić Z. Selecting the Size of the Universal Reducer, Taking into Account its Thermal Load Capacity. Tehnički vjesnik [Internet]. 2018 [pristupljeno 27.05.2019.];25(6):1829-1836. doi: https://doi.org/10.17559/TV-20170329230603
IEEE
M. Rackov, S. Kuzmanović i Z. Anišić, "Selecting the Size of the Universal Reducer, Taking into Account its Thermal Load Capacity", Tehnički vjesnik, vol.25, br. 6, str. 1829-1836, 2018. [Online]. doi: https://doi.org/10.17559/TV-20170329230603

Sažetak
Universal helical gear motors are among mechanisms that operate with a very high efficiency (about 0.98 per gear pair) [1, 2] and thus their thermal power capacity has not received enough attention, even in the cases when they overheat (usually at higher ambient temperature and high power motors). Therefore, it is necessary to define the thermal capacity in the catalogues of the speed reducer with a solid input shaft, as it is done by worm and helical-worm gear units which operate with much lower efficiency. Some manufacturers [3] pay necessary attention to this factor and thus enable the proper selection of gear reducers; this means they have prepared certain procedures to be undertaken if such occasion occurs, in order to overcome possible problems that may arise due to overheating the gear reducer. With this approach in the universal gear unit selection, some positive benefits can be surely achieved in the market of gear reducers, and that should not be ignored.

Ključne riječi
thermal capacity; universal gear reducer

Hrčak ID: 212840