Skoči na glavni sadržaj

Prethodno priopćenje

https://doi.org/10.31803/tg-20200629122146

Comparison of Power Distribution, Losses and Efficiencies of a Steam Turbine with and without Extractions

Vedran Mrzljak orcid id orcid.org/0000-0003-0323-2600 ; Faculty of Engineering, University of Rijeka, Vukovarska 58, 51000 Rijeka, Croatia
Sandi Baressi Šegota orcid id orcid.org/0000-0002-3015-1024 ; Faculty of Engineering, University of Rijeka, Vukovarska 58, 51000 Rijeka, Croatia
Hrvoje Meštrić ; Catholic University of Croatia, University of Zagreb, Ilica 242, 10000 Zagreb, Croatia
Zlatan Car orcid id orcid.org/0000-0003-2817-9252 ; Faculty of Engineering, University of Rijeka, Vukovarska 58, 51000 Rijeka, Croatia


Puni tekst: engleski pdf 1.174 Kb

str. 480-487

preuzimanja: 443

citiraj


Sažetak

The paper presents an analysis of two steam turbine operation regimes - regime with all steam extractions opened (base process) and regime with all steam extractions closed. Closing of all steam extractions significantly increases turbine real developed power for 5215.88 kW and increases turbine energy and exergy losses with simultaneous decrease of turbine energy and exergy efficiencies for more than 2%. First extracted steam mass flow rate has a dominant influence on turbine power losses (in comparison to turbine maximum power when all of steam extractions are closed). Cumulative power losses caused by steam mass flow rate extractions are the highest in the fourth turbine segment and equal to 1687.82 kW.

Ključne riječi

efficiencies; losses; power distribution; steam extractions; steam turbine

Hrčak ID:

247421

URI

https://hrcak.srce.hr/247421

Datum izdavanja:

9.12.2020.

Posjeta: 1.072 *