Skoči na glavni sadržaj

Izvorni znanstveni članak

The statistical scatter of breakdown voltages of transformer oil - Part III

Vitaly Gurin
Marius Grisaru


Puni tekst: engleski pdf 1.099 Kb

str. 28-38

preuzimanja: 320

citiraj


Sažetak

The third part of the article about coefficients of variation (CV%) of breakdown voltage (BDV) of transformer oil discusses area effect and volume effect. Apparently, BDV decreases linearly with area on a logarithmic scale, but this does not apply to CV%. There is currently little data to make any quantitative recommendations. With an increase in the stressed oil volume by orders of magnitude, CV% decreases several times, but this estimate requires verification.

Ključne riječi

area effect; breakdown voltage; coefficients of variation; electric strength; transformer oil; stressed oil volume

Hrčak ID:

330330

URI

https://hrcak.srce.hr/330330

Datum izdavanja:

7.4.2025.

Posjeta: 493 *