Izvorni znanstveni članak
CR-39 (DOP): its response and charge resolution for the detection of heavy ions
Deba P. Bhattacharyya
; Indian Association for the Cultivation of Science, Calcutta 700 032, India
Pratibha Pal
; Indian Association for the Cultivation of Science, Calcutta 700 032, India
Basudhara Basu
; Indian Association for the Cultivation of Science, Calcutta 700 032, India
Ruma Raksidt
; Indian Association for the Cultivation of Science, Calcutta 700 032, India
S. C. Mukherjee
; Indian Association for the Cultivation of Science, Calcutta 700 032, India
A. K. Ganguly
; Department of Physics, University College of Science, Calcutta 700 009, India
Biva Chowdhuri
; Department of Physics, University College of Science, Calcutta 700 009, India
S. Biswas
; Tata Institute of Fundamental Research, Bombay 400 005, India
N. Durgaprasad
; Tata Institute of Fundamental Research, Bombay 400 005, India
Sažetak
The response and charge resolution for the detection of near relativistic heavy ions have been investigated using the fragmented beam of 1.88 A GeV 56Fe nuclei from LBL Bevalac. The average experimental charge resolution has been found to be 0.37e for 22 < Z < 28 in place of average intrinsic charge resolution which is ≈ 0. 19e for single etch pit diameter measurement. Our observations are in accord with those obtained by other workers.
Ključne riječi
Hrčak ID:
331475
URI
Datum izdavanja:
8.1.1989.
Posjeta: 497 *