Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.14256/JCE.4531.2026

Leak location and magnitude estimation in water distribution networks using an optimised two-stage leak localisation model

Hillary M. Zodape
Shilpa R. Dongre


Puni tekst: hrvatski pdf 2.339 Kb

str. 471-486

preuzimanja: 0

citiraj

Puni tekst: engleski pdf 2.237 Kb

str. 471-486

preuzimanja: 0

citiraj


Sažetak

Water loss from urban water distribution networks (WDNs) challenges sustainable water management and utility operations. Early leak detection and accurate localisation are crucial for reducing non-revenue water and maintaining network efficiency. This study proposes a machine learning-based framework integrating EPANET-generated static hydraulic simulations with an artificial neural network (ANN) optimised using particle swarm optimisation (PSO) for effective feature extraction. Pressure data under various leak and no-leak scenarios were simulated, and sensitive sensor nodes were strategically selected to enhance accuracy. By bridging simulation and reality, this method successfully integrates hydraulic modelling with data-driven learning, demonstrating the hybrid framework’s strong potential for scalable and accurate leak detection, localisation, and magnitude estimation in WDNs.

Ključne riječi

water distribution network; hybrid machine learning; PSO; leak localization; leak magnitude

Hrčak ID:

352356

URI

https://hrcak.srce.hr/352356

Datum izdavanja:

22.10.2026.

Podaci na drugim jezicima: hrvatski

Posjeta: 0 *