Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.5552/drind.2012.1213

The Effect of Residual Swelling after Drying on Internal Bond in OSB

Radosław Mirski orcid id orcid.org/0000-0002-4881-579X ; Fakultet drvne tehnologije Sveučilišta bioloških znanosti u Poznanju, Poljska
Jerzy Majka orcid id orcid.org/0000-0002-6713-8077 ; Fakulteta drvne tehnologije Sveučilišta bioloških znanosti u Poznanju, Poljska.
Dorota Dziurka orcid id orcid.org/0000-0001-6197-7825 ; Fakulteta drvne tehnologije Sveučilišta bioloških znanosti u Poznanju, Poljska.


Puni tekst: engleski pdf 633 Kb

str. 241-247

preuzimanja: 1.494

citiraj


Sažetak

The study determined the effect of non-recoverable thickness swelling (NTS) on internal bond in oriented strand boards (OSB). The tests were conducted taking into consideration different time variants, ranging from 1 to 70 h, of soaking in water at 20ºC. The analysis of the results recorded for measured non-recoverable thickness swelling indicates that the observed reduction of strength is a result of changes occurring in the core of boards. Moreover, a linear IB/NTS dependence was observed for OSB/3 and OSB/4 of 15 mm in thickness.

Ključne riječi

OSB; thickness swelling; internal bond; non-recoverable swelling

Hrčak ID:

93598

URI

https://hrcak.srce.hr/93598

Datum izdavanja:

14.12.2012.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.744 *