Skoči na glavni sadržaj

Izvorni znanstveni članak

Comparison of Ventilation Threshold and Heart Rate Deflection Point in Fast and Standard Treadmill Test Protocols

Vlatko Vučetić
Davor Šentija
Goran Sporiš
Nebojša Trajković
Zoran Milanović


Puni tekst: engleski pdf 740 Kb

str. 190-202

preuzimanja: 1.548

citiraj


Sažetak

The purpose of this study was to compare two methods for determination of anaerobic threshold from two different treadmill protocols. Forty-eight Croatian runners of national rank (ten sprinters, fifteen 400-m runners, ten middle distance runners and thirteen long distance runners), mean age 21.7}5.1 years, participated in the study. They performed two graded maximal exercise tests on a treadmill, a standard ramp treadmill test (TSR, speed increments of 1 km•h-1 every 60 seconds) and a fast ramp treadmill test (TFR, speed increments of 1 km•h-1 every 30 seconds) to determine and compare the parameters at peak values and at heart rate at the deflection point (HR DP) and ventilation threshold (VT ). There were no significant differences between protocols (p>0.05) for peak values of oxygen uptake (VO2max, 4.48±0.43 and 4.44±0.45 L•min-1), weight related VO2max (62.5±6.2 and 62.0±6.0 mL•kg-1•min-1), pulmonary ventilation (VE max, 163.1}18.7 and 161.3}19.9 L•min-1) and heart rate (HR max, 192.3}8.5 and 194.4}8.7 bpm) (TFR and TSR, respectively). Moreover, no significant differences between TFR and TSR where found for VT and HR DP when expressed as VO2 and HR . However, there was a significant effect of ramp slope on running speed at VO2max and at the anaerobic threshold (AnT) , independent of the method used (VT : 16.0}2.2 vs 14.9}2.2 km•h-1;HR DP: 16.5}1.9 vs 14.9±2.0 km•h-1 for TFR and TSR respectively). Linear regression analysis revealed high between-test and between-method correlations for VO2, HR and running speed parameters (r=0.78-0.89, p<0.01). The present study has indicated that the VT and HR DP for running (VO2, ventilation, and heart rate at VT /HR DP) are independent of test protocol, while there is a significant effect of ramp slope on VT and HR DP when expressed as running speed. Moreover, this study demonstrates that the point of deflection from linearity of heart rate may be an accurate predictor of the anaerobic threshold in trained runners, independently of the protocol used.

Ključne riječi

Exercise test; Anaerobic threshold; Treadmill test; Heart rate; Pulmonary ventilation

Hrčak ID:

127625

URI

https://hrcak.srce.hr/127625

Datum izdavanja:

1.7.2014.

Podaci na drugim jezicima: hrvatski

Posjeta: 3.333 *