APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM
G. Jerbić
Puni tekst: hrvatski pdf 1.100 Kb
str. 216-231
preuzimanja: 1.954
citiraj
APA 6th Edition
Jerbić, G. (2007). APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM. Journal of Energy, 56 (2), 216-231. Preuzeto s https://hrcak.srce.hr/13155
MLA 8th Edition
Jerbić, G.. "APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM." Journal of Energy, vol. 56, br. 2, 2007, str. 216-231. https://hrcak.srce.hr/13155. Citirano 21.11.2024.
Chicago 17th Edition
Jerbić, G.. "APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM." Journal of Energy 56, br. 2 (2007): 216-231. https://hrcak.srce.hr/13155
Harvard
Jerbić, G. (2007). 'APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM', Journal of Energy, 56(2), str. 216-231. Preuzeto s: https://hrcak.srce.hr/13155 (Datum pristupa: 21.11.2024.)
Vancouver
Jerbić G. APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM. Journal of Energy [Internet]. 2007 [pristupljeno 21.11.2024.];56(2):216-231. Dostupno na: https://hrcak.srce.hr/13155
IEEE
G. Jerbić, "APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM", Journal of Energy, vol.56, br. 2, str. 216-231, 2007. [Online]. Dostupno na: https://hrcak.srce.hr/13155. [Citirano: 21.11.2024.]
Puni tekst: engleski pdf 1.100 Kb
str. 216-231
preuzimanja: 798
citiraj
APA 6th Edition
Jerbić, G. (2007). APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM. Journal of Energy, 56 (2), 216-231. Preuzeto s https://hrcak.srce.hr/13155
MLA 8th Edition
Jerbić, G.. "APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM." Journal of Energy, vol. 56, br. 2, 2007, str. 216-231. https://hrcak.srce.hr/13155. Citirano 21.11.2024.
Chicago 17th Edition
Jerbić, G.. "APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM." Journal of Energy 56, br. 2 (2007): 216-231. https://hrcak.srce.hr/13155
Harvard
Jerbić, G. (2007). 'APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM', Journal of Energy, 56(2), str. 216-231. Preuzeto s: https://hrcak.srce.hr/13155 (Datum pristupa: 21.11.2024.)
Vancouver
Jerbić G. APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM. Journal of Energy [Internet]. 2007 [pristupljeno 21.11.2024.];56(2):216-231. Dostupno na: https://hrcak.srce.hr/13155
IEEE
G. Jerbić, "APPLICATION OF PHASE SHIFTING TRANSFORMERS IN THE CROATIAN POWER SUPPLY SYSTEM", Journal of Energy, vol.56, br. 2, str. 216-231, 2007. [Online]. Dostupno na: https://hrcak.srce.hr/13155. [Citirano: 21.11.2024.]
Sažetak
The phase shifting transformers with on load tap changer are increasingly found in modern power supply systems, especially under the present conditions of the full opening of the electricity market. The construction of the Žerjavinec TS 400/220/110 kV for the first time introduces into the Croatian transmission system a 400/220/(10,5) kV 400 MVA phase shifting network transformer with on load tap changer. The present article highlights some specific aspects of phase shifting transformers in the light of their application in the Croatian system. For a more efficient use of the advantages of phase shifting transformers, the transformer of this type at Žerjavinec would need to be provided with a complementary transformer (pair), either within the Croatian transmission network or within the neighbouring systems.
Ključne riječi
coordinated control; phase shifting transformer; transmission network