Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.17559/TV-20140213152946

Study on the application of cleaning models with high speed water jets to CIP-processes

Hannes Köhler orcid id orcid.org/0000-0001-9391-4407 ; Technische Universität Dresden, Faculty of Mechanical Engineering, Institute of Processing Machines and Mobile Machines, Bergstraße 120, 01062 Dresden, Germany
Hannes Stoye ; Technische Universität Dresden, Faculty of Mechanical Engineering, Institute of Processing Machines and Mobile Machines, Bergstraße 120, 01062 Dresden, Germany
Thomas Weyrauch ; Fraunhofer IVV Dresden, Branch Lab for Processing Machinery and Packaging Technology AVV, Heidelberger Straße 20, 01189 Dresden, Germany
André Boye ; Fraunhofer IVV Dresden, Branch Lab for Processing Machinery and Packaging Technology AVV, Heidelberger Straße 20, 01189 Dresden, Germany
Marc Mauermann ; Fraunhofer IVV Dresden, Branch Lab for Processing Machinery and Packaging Technology AVV, Heidelberger Straße 20, 01189 Dresden, Germany
Jens-Peter Majschak ; (1) Technische Universität Dresden, Faculty of Mechanical Engineering, Institute of Processing Machines and Mobile Machines, Bergstraße 120, 01062 Dresden, Germany; (2) Fraunhofer IVV Dresden, Branch Lab for Processing Machinery and Packaging Technology A


Puni tekst: hrvatski pdf 1.006 Kb

str. 349-355

preuzimanja: 448

citiraj

Puni tekst: engleski pdf 1.006 Kb

str. 349-355

preuzimanja: 865

citiraj


Sažetak

To meet consumer safety and high product quality there is a need of reliable cleaning processes in the food industry. To keep competitive position it is necessary to control costs of those cleaning in place (CIP) processes e.g. expenses for fresh and waste water, detergents and to minimize downtime of the production facilities. The removal of food soils with water droplet sprays are very little researched, especially the mathematical modelling. In this paper we show that the high pressure model of Leu et al. can be applied to low pressure spray cleaning of a food soil with marginal adaptations. We used an existing analytical model for the relation of cleaned width as a function of the standoff distance and considered the different structure of the water spray as well as a food specific cleaning behaviour. We validated the analytical model with experimental results by varying the equivalent nozzle diameter.

Ključne riječi

CIP; cleaning model; spray; water jet

Hrčak ID:

156820

URI

https://hrcak.srce.hr/156820

Datum izdavanja:

27.4.2016.

Podaci na drugim jezicima: hrvatski

Posjeta: 3.248 *