Izvorni znanstveni članak
https://doi.org/10.24138/jcomss.v3i2.260
Installation Uncertainty of Field Level Calculation around a Base Station Antenna
Antonio Šarolić
orcid.org/0000-0001-7941-1977
; University of Split, Faculty of Electotehnical Engineering, Mechanical Engineering and Naval Architecture, Split, Croatia
Borivoj Modlic
; University of Zagreb, Faculty of Electotehnical Engineering and Computing, Zagreb, Croatia
Sažetak
In the near field, the antenna pattern provided by the antenna manufacturer is generally not applicable, or should be considered with caution, even for the single antenna in free space. In the real life, antenna is often surrounded by other conductive objects in the immediate vicinity. These objects tend to distort the antenna radiation pattern. Since the electromagnetic field calculation for the coverage or radiation hazard analysis depends on the three-dimensional antenna gain, this effect should be taken into account. This paper suggests the use of "installation uncertainty" that should be added to the field calculation. The amount of this quantity depends on the installation geometry and can be calculated numerically for a specific situation. This paper shows the results of numerical calculations for some typical antenna installation geometries.
Ključne riječi
radiation hazard; base station antenna radiation pattern; near field
Hrčak ID:
180583
URI
Datum izdavanja:
21.6.2007.
Posjeta: 1.579 *