Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.17559/TV-20151022121953

Robustness of contact-less optical method, used for measuring contact wire position in changeable lighting conditions

Jacek Skibicki orcid id orcid.org/0000-0003-1373-0961 ; Gdansk University of Technology, Faculty of Electrical and Control Engineering, Department of Electrical Engineering in Transport, ul. G. Narutowicza 11/12, 80-233, Gdańsk, Poland


Puni tekst: hrvatski pdf 6.034 Kb

str. 1759-1768

preuzimanja: 545

citiraj

Puni tekst: engleski pdf 6.034 Kb

str. 1759-1768

preuzimanja: 471

citiraj


Sažetak

The article presents verification of robustness of contactless method based on 2D image camera, which is used to measure catenary contact wire position in changeable ambient lighting conditions. Robustness in changeable lighting conditions is ensured through the combination of advanced image processing for background information removal and the algorithm of error correction. This algorithm detects incorrect images and substitutes information from these images with proper measurement data obtained from correct images which precede and follow the incorrect one. The paper presents and discusses the processing algorithms used, as well as shows examples of measurement results obtained on a full scale laboratory stand.

Ključne riječi

contact line; diagnostic systems; electric traction; measurement systems

Hrčak ID:

190172

URI

https://hrcak.srce.hr/190172

Datum izdavanja:

3.12.2017.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.305 *