Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.17559/TV-20180618231334

Multi Domain Matrix (MDM) of the Vertical Hydrogenerator

Ivan Triplat ; KONČAR Generators and Motors Inc. Fallerovo šetalište 22, 10000 Zagreb, Croatia
Dorian Marjanović orcid id orcid.org/0000-0002-5011-0377 ; Faculty of Mechanical Engineering and Naval Architecture Ivana Lučića 5, 10000 Zagreb, Croatia
Lucijan Stamać orcid id orcid.org/0000-0003-4747-1849 ; Faculty of Mechanical Engineering and Naval Architecture Ivana Lučića 5, 10000 Zagreb, Croatia


Puni tekst: engleski pdf 2.237 Kb

str. 1023-1030

preuzimanja: 832

citiraj


Sažetak

Purpose of this work was to show connections between vertical hydrogenerator design parameters. Authors made DSM (Design Structure Matrix), to show design parameters dependencies, first matrix size was reduced and it does not consist of all design parameters, it consists only of more relevant design parameters to be solvable. Final size of matrix is 221×221. Matrix shows that electrical generator in some ideal conditions could have almost straightforward path during design procedure. DSM matrix is still in process of verification. After finishing DSM of design parameters, authors made MDM (Multi Domain Matrix) which connects design parameters with mechanical calculations and generator main drawings. This matrix has the purpose to help managers, electrical design experts, other design experts and any others who should not need knowledge about generator design process to easily track changes between parameters and to see how change of some parameter affects drawings and calculations. At the end authors made VBA program which visually shows connections.

Ključne riječi

design parameters; Design Structure Matrix (DSM); Multi Domain Matrix (MDM); vertical hydrogenerator

Hrčak ID:

223297

URI

https://hrcak.srce.hr/223297

Datum izdavanja:

25.7.2019.

Posjeta: 1.850 *