Skoči na glavni sadržaj

Prethodno priopćenje

https://doi.org/10.14256/JCE.2524.2018

Seismic load tests on exterior beam-column connections of existing RC structures

Turgay Cosgun
Cumhur Cosgun
Abdulrauf Kanishka
Atakan Mangir
Baris Sayin
Ahmet Murat Türk


Puni tekst: engleski pdf 1.300 Kb

str. 1129-1141

preuzimanja: 374

citiraj

Puni tekst: hrvatski pdf 1.320 Kb

str. 1129-1141

preuzimanja: 1.000

citiraj


Sažetak

Suggestions for improving seismic performance of beam-column connections of the existing RC structures are presented in this paper. The use of low-strength concrete with plain bars without stirrups in joints is analysed, and behaviour of joints in the aforementioned conditions under cyclic load is investigated. Five specimens with different reinforcement configurations were produced and tested in the experimental process. Based on results, it was concluded that critical parameters for the performance of existing structures are: stirrup arrangement in joints, and the use of at least 90-degree hooks in longitudinal reinforcement of beams.

Ključne riječi

RC beam-column joint; low-strength concrete; cyclic load; experimental study

Hrčak ID:

232068

URI

https://hrcak.srce.hr/232068

Datum izdavanja:

13.1.2020.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.004 *