Prethodno priopćenje
https://doi.org/10.17818/NM/2021/1.3
Optimized Marine Fresh Water Generator Control System
Predrag Kralj
orcid.org/0000-0001-7777-6358
; University of Rijeka, Faculty of Maritime Studies, Rijeka, Croatia
Dragan Martinović
; University of Rijeka, Faculty of Maritime Studies, Rijeka, Croatia
Mato Tudor
; University of Rijeka, Faculty of Maritime Studies, Rijeka, Croatia
Davor Lenac
; University of Rijeka, Faculty of Maritime Studies, Rijeka, Croatia
Sažetak
The introductory part of this paper offers an overview of approaches to the management of marine fresh water generator and points out the most important factors influencing the processes. The second part deals with operation time and total overhaul time both influenced by evaporation intensity. Comparison and simple calculation are made of several distinct modes of operation assuming days in voyage and hours necessary for overhaul. Next section gives a thermal analysis of the processes, resulting in energy balance equation that could be used as a base for the optimal control system for one single-stage unit. In fact, the suggested control system is based on the energy balance equation that is given in this section. In the fourth part the analysis of the most important operational values is made. The changes recorded on the six-channel plotter are used to evaluate the suggested control system. The paper gives an example of optimal control system for the single stage fresh water generator and suggests further research.
Ključne riječi
energy; control system; marine fresh water generator; optimization
Hrčak ID:
251895
URI
Datum izdavanja:
9.2.2021.
Posjeta: 1.482 *