Skoči na glavni sadržaj

Prethodno priopćenje

https://doi.org/10.14256/JCE.3503.2022

Performance of reinforced engineered cementitious composite square columns

Mohsen Dayyani
Alireza Mortezaei
Mohammad Sadegh Rohanimanesh
Jafar Asgari Marnani


Puni tekst: hrvatski pdf 3.523 Kb

str. 13-21

preuzimanja: 171

citiraj

Puni tekst: engleski pdf 3.513 Kb

str. 13-21

preuzimanja: 76

citiraj


Sažetak

This paper investigates the effects of aspect ratio and fibre fraction on the failure of engineered cementitious composite (ECC) concrete columns. When subjected to cyclic load, these columns may fail due to the strain-hardening of longitudinal bars or the formation of dominant cracks. In this experiment, 11 ECC columns with fibre fractions between 0–1.5 % and aspect ratios from 3–7, as well as a single reinforced concrete column, were tested. The results showed that both aspect ratio and fibre fraction significantly impacted the failure paths observed. Additionally, the ECC columns exhibited a cumulative energy dissipation capacity approximately 100 % higher than that of the conventional concrete column.

Ključne riječi

engineered cementitious composite; square column; fibre fraction; aspect ratio; failure path

Hrčak ID:

294599

URI

https://hrcak.srce.hr/294599

Datum izdavanja:

1.3.2023.

Podaci na drugim jezicima: hrvatski

Posjeta: 478 *