Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.17559/TV-20260320003471

Integrated Assessment of Flammability and Fire Effluent Profiles of Acoustic Insulation Materials

Nikola Mišić ; University of Niš, Faculty of Occupational Safety, Čarnojevića 10A, 18000 Niš, Serbia
Miomir Raos ; University of Niš, Faculty of Occupational Safety, Čarnojevića 10A, 18000 Niš, Serbia *
Roumen Iankov ; Bulgarian Academy of Sciences, Institute of Mechanics, Acad. G. Bontchev St., bl. 4, 1113 Sofia, Bulgaria
Viša Tasić ; Mining and Metallurgy Institute Bor, Alberta Ajnštajna 1, 19210 Bor, Serbia
Silvana Dimitrijević ; Mining and Metallurgy Institute Bor, Alberta Ajnštajna 1, 19210 Bor, Serbia
Marjan Popović ; MIPHEM d.o.o., Matice srpske 57e, 11050, Belgrade, Serbia
Milan Protić ; University of Niš, Faculty of Occupational Safety, Čarnojevića 10A, 18000 Niš, Serbia *

* Dopisni autor.


Puni tekst: engleski pdf 1.779 Kb

str. 2231-2244

preuzimanja: 0

citiraj


Sažetak

This study presents an integrated assessment of the flammability and fire effluent profiles of five acoustic insulation materials with different structures and compositions. The materials were characterized by SEM/EDS, XRF, C/S analysis, and ATR-FTIR, whereas their fire behavior was evaluated using a mass loss calorimeter coupled with FTIR gas analysis, enabling simultaneous bench-scale flammability testing and real-time monitoring of fire effluents. Pronounced differences were observed across the sample set. Samples S4 and S5 exhibited the shortest times to ignition and the highest peak combustion intensity, whereas S3 showed by far the weakest overall fire response. Fire effluent analysis further revealed distinct emission patterns: S1 was characterized by the strongest combined CO and CH4 formation, S4 and S5 by CO2- and NO-dominated profiles with temporally concentrated emissions, and S3 by the weakest and most compositionally distinct effluent response. Exploratory composition-response analysis indicated that silica-related contribution was associated with weaker peak burning and reduced formation of the main oxidized effluents. Overall, the results demonstrate that the fire hazard of acoustic insulation materials cannot be adequately described by a single flammability parameter alone, but requires integrated consideration of combustion intensity, gas speciation, and temporal effluent development.

Ključne riječi

acoustic insulation materials; fire effluents; flammability; FTIR gas analysis; heat release rate; mass loss calorimeter

Hrčak ID:

353059

URI

https://hrcak.srce.hr/353059

Datum izdavanja:

7.11.2026.

Posjeta: 0 *