Skoči na glavni sadržaj

Izvorni znanstveni članak

Methods for monitoring heat flow intensity in the blast furnace wall

L'. Dorčák ; BERG - Faculty, Technical University of Košice, Košice, Slovakia
J. Terpák ; BERG - Faculty, Technical University of Košice, Košice, Slovakia
I. Podlubný ; BERG - Faculty, Technical University of Košice, Košice, Slovakia
L. Pivka ; BERG - Faculty, Technical University of Košice, Košice, Slovakia


Puni tekst: engleski pdf 277 Kb

str. 75-78

preuzimanja: 1.655

citiraj


Sažetak

In this paper we present the main features of an online system for real-time monitoring of the bottom part of the blast furnace. Firstly, monitoring concerns the furnace walls and furnace bottom temperatures measurement and their visualization. Secondly, monitored are the heat flows of the furnace walls and furnace bottom. In the case of two measured temperatures, the heat flow is calculated using multi-layer implicit difference scheme and in the case of only one measured temperature, the heat flow is calculated using a method based on application of fractional-order derivatives. Thirdly, monitored is the theoretical temperature of the blast furnace combustion process in the area of tuyeres.

Ključne riječi

blast furnace; thermal load; real-time monitoring; heat fluxes; isotherms

Hrčak ID:

43644

URI

https://hrcak.srce.hr/43644

Datum izdavanja:

1.4.2010.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.994 *