Energy Analysis of Main Propulsion Steam Turbine from Conventional LNG Carrier at Three Different Loads

Vedran Mrzljak orcid id orcid.org/0000-0003-0323-2600 ; University of Rijeka Faculty of Engineering Rijeka
Igor Poljak orcid id orcid.org/0000-0001-8749-4223 ; University of Zadar Department of Maritime Sciences Zadar


Full text: english pdf 2.945 Kb

page 10-18

downloads: 1.009

cite


Abstract

This paper presents energy analysis of entire marine main propulsion steam turbine and both of its cylinders at three different loads. Marine steam propulsion plant in which main turbine operates is described in detail. Measured data from real exploitation at each required turbine operating point enables calculation of energy losses and efficiencies. Real developed power distribution between both turbine cylinders is not the same at all observed loads. Energy losses and efficiencies of main turbine cylinders and entire main steam turbine increases during the increase in turbine load. An increase in turbine load resulted with in a sharp increase in energy efficiency of HPC (High Pressure Cylinder) from 51.01 % to 74.13 %, while the increase in energy efficiency of LPC (Low Pressure Cylinder) is not as sharp (from 73.88 % to 78.50 %). The change in energy efficiency of the entire main steam turbine during the load increase (from 65.54 % to 79.45 %) is mostly influenced by a change in energy efficiency of HPC. Energy loss and real developed power ratio is reversely proportional to energy efficiencies and losses of both steam turbine cylinders and the entire turbine.

Keywords

main marine steam turbine; marine propulsion plant; energy analysis; change in load conditions

Hrčak ID:

217462

URI

https://hrcak.srce.hr/217462

Publication date:

26.2.2019.