Skip to the main content

Original scientific paper

https://doi.org/10.5599/jese.849

A simple and fast method to detect freebase cocaine in artificial saliva by square wave voltammetry (SWV) using carbon paste electrode

Bruno Ferreira orcid id orcid.org/0000-0001-7047-3143 ; GEEQFor – Grupo de Eletroquímica, Eletroanalítica e Química Forense, Departamento de Química - Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, 14040-901 - Ribeirão Preto, São Paulo, Brasil
Leandro Oka Duarte ; GEEQFor – Grupo de Eletroquímica, Eletroanalítica e Química Forense, Departamento de Química - Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, 14040-901 - Ribeirão Preto, São Paulo, Brasil
Érica Naomi Oiye ; GEEQFor – Grupo de Eletroquímica, Eletroanalítica e Química Forense, Departamento de Química - Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, 14040-901 - Ribeirão Preto, São Paulo, Brasil
Maria Fernanda Muzetti Ribeiro orcid id orcid.org/0000-0003-3991-4638 ; GEEQFor – Grupo de Eletroquímica, Eletroanalítica e Química Forense, Departamento de Química - Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, 14040-901 - Ribeirão Preto, São Paulo, Brasil
Juliana Midori Toia Katayama ; GEEQFor – Grupo de Eletroquímica, Eletroanalítica e Química Forense, Departamento de Química - Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, 14040-901 - Ribeirão Preto, São Paulo, Brasil
Pedro Henrique Barros Oliva ; GEEQFor – Grupo de Eletroquímica, Eletroanalítica e Química Forense, Departamento de Química - Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, 14040-901 - Ribeirão Preto, São Paulo, Brasil
Marcelo Firmino de Oliveira ; GEEQFor – Grupo de Eletroquímica, Eletroanalítica e Química Forense, Departamento de Química - Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, 14040-901 - Ribeirão Preto, São Paulo, Brasil


Full text: english pdf 810 Kb

page 361-371

downloads: 497

cite


Abstract

The consequences of consuming and commercializing illicit drugs including cocaine, con­stitute a serious problem for authorities and the whole society. Cocaine is usually identified in the laboratory conditions by chromatographic or spectroscopic methods. Electro­che­mical techniques have also gained prominence because they are fast and easy to use, have many applications, and provide reproducible and reliable results. Therefore, in the present study, a voltammetric method was developed to detect freebase cocaine using carbon paste electrode and methanol as the main cocaine solvent. The developed method was applied to detect cocaine in the artificial saliva by the square wave voltammetry (SWV). The current values increased linearly with the concentration of cocaine, which afforded construction of the analytical curve. The limit of detection (LoD) and the limit of quantify­cation (LoQ) were determined as 0.90 µg/mL and 2.41 µg/mL, respectively. For compa­rison purposes, HPLC-DAD chromatographic method was also applied to detect cocaine. The corresponding analytical curve gave LoD = 0.043 µg/mL and LoQ = 0.130 µg/mL. Although showing better analytical results, HPLC-DAD method could not detect cocaine in saliva samples without previous treatment, what makes the electrochemical method much more attractive for this type of detection.

Keywords

Forensic chemistry; cocaine; saliva; square wave voltammetry

Hrčak ID:

242262

URI

https://hrcak.srce.hr/242262

Publication date:

29.7.2020.

Visits: 1.321 *