Skip to the main content

Original scientific paper

https://doi.org/10.17113/ftb.59.04.21.7179

The Influence of High-Power Ultrasound and Bactofugation on Microbiological Quality of Milk

Edita Juraga orcid id orcid.org/0000-0002-1177-8913 ; ATERA d.o.o., Ivane Brlić Mažuranić 25, 42000 Varaždin, Croatia
Višnja Stulić orcid id orcid.org/0000-0002-6203-1473 ; Faculty of Food Technology and Biotechnology, University of Zagreb, Pierottjeva 6, 10000 Zagreb, Croatia
Tomislava Vukušić Pavičić orcid id orcid.org/0000-0001-8014-4124 ; Faculty of Food Technology and Biotechnology, University of Zagreb, Pierottjeva 6, 10000 Zagreb, Croatia
Jasenka Gajdoš Kljusurić orcid id orcid.org/0000-0001-6657-7337 ; Faculty of Food Technology and Biotechnology, University of Zagreb, Pierottjeva 6, 10000 Zagreb, Croatia
Mladen Brnčić orcid id orcid.org/0000-0002-8906-4291 ; Faculty of Food Technology and Biotechnology, University of Zagreb, Pierottjeva 6, 10000 Zagreb, Croatia
Zoran Herceg orcid id orcid.org/0000-0003-3967-6676 ; Faculty of Food Technology and Biotechnology, University of Zagreb, Pierottjeva 6, 10000 Zagreb, Croatia


Full text: english pdf 433 Kb

page 454-462

downloads: 285

cite

Download JATS file


Abstract

Research background. The application of high power ultrasound combined with a slightly increased temperature on raw cow’s milk, skimmed cow’s milk and skimmed cow’s milk that passed the bactofugation process was analysed. We combined ultrasound with bactofugation of milk to achieve the microbiological accuracy that is equivalent to pasteurization.
Experimental approach. The milk samples (200 mL) were treated for 2.5, 5, 7.5 and 10 min with high-power ultrasound (200 and 400 W) with a frequency of 24 kHz. The treatments were conducted with a constant duty cycle of 100%. Temperatures during the treatments were 20 and 55 °C. The somatic cell count of the aerobic mesophilic bacteria, as well the number of Enterobacteriaceae, Escherichia coli and Staphylococcus aureus cells were analysed.
Results and conclusions. From the perspective of the reduction of the total count of bacteria, the best result was achieved by high-power ultrasound at 400 W treated for 10 min. High reduction of Enterobacteriaceae, E. coli and S. aureus cells was achieved with ultrasound treatment of raw, skimmed and skimmed cow’s milk that passed the bactofugation with a power of 200 and 400 W regardless of the treatment time.
Novelty and scientific contribution. This work combines bactofugation and high-power ultrasound for the inactivation of microoganisms. This combination was used at a slightly increased temperature (up to 55 °C), which is much more economical than pasteurization, while it preserves the sensory and physicochemical properties of milk.

Keywords

high-power ultrasound; microbiological safety of milk; technology of bactofugation

Hrčak ID:

270307

URI

https://hrcak.srce.hr/270307

Publication date:

22.12.2021.

Article data in other languages: croatian

Visits: 1.487 *




INTRODUCTION

Milk is a biological fluid that deserves special attention as the most complete natural fluid (1). It is an ideal medium for the development of undesirable microorganisms (2). To ensure the safety of food, raw milk needs to be controlled by conducting chemical and microbiological analyses which determine its quality. If the microbiological analysis reveals more than 105 CFU/mL microorganisms in raw milk, the result indicates a lack of hygienic conditions (3), and the somatic cell count (SCC) in 1 mL must be ≤400 000, observed as a geometric average over three months.

The Food and Agriculture Organization of the United Nations and the World Health Organization define various thermal procedures that are carried out to reduce and remove the number of microorganisms from milk (4). The most common processes are continuous flow pasteurization and ultra-high temperature (UHT) treatment. However, significant effects of heat treatment of milk are vitamin degradation, whey protein denaturation and Maillard reaction (due to protein and lactose reaction). Therefore, it is extremely important to use lower temperatures with the same or higher efficiency as pasteurization and/or sterilization.

Bactofugation is used to improve the bacteriological quality of raw milk. It belongs to mechanical processes, and is used in the production of pasteurized and UHT milk. This process reduces the primary number of heat-resistant microorganisms in milk before heat treatment, all to prolong the shelf life of milk using a milder temperature regime (5). The optimal temperature of bactofugation, at which the best results are achieved, is 55–60 °C.

Today, non-thermal methods as the high-power ultrasound (6,7) treatment with high hydrostatic pressure, pulsed electric and magnetic fields are often used in food industry. High hydrostatic pressure is commercially applied in food processing, and ultrasound is applied in homogenization, emulsification and dispersion processes (8). New non-thermal methods can significantly save energy and shorten the duration of the production. The use of high-power ultrasound has shown several advantages over heat treatment by pasteurization, such as minimizing taste loss in juices, greater homogeneity and significant energy savings (9). During the high-power ultrasound processing, acoustic energy transfer is instantaneous and extends through the entire volume, which results in lower energy consumption (6). When using low-intensity ultrasound waves, the mechanism of microorganism inactivation is based on changing the metabolism of microorganism cells, while the mechanism of microorganism inactivation using high-power ultrasound waves is based on breaking cell membranes of microorganisms and denaturation of enzymes (10,11).

Therefore, the aim of this paper is to examine the possibility of processing raw and skimmed milk using high-power ultrasound in combination with slightly elevated temperature and pretreated with bactofugation in order to achieve microbiological safety at the level achieved by pasteurization.

MATERIALS AND METHODS

Milk samples

Throughout the research, milk at different stages of processing was used, sampled directly from production, where bactofugation is an integral part of the milk processing.

All tests were performed on cow's milk from the same production batch from the dairy Vindija plc (Varaždin, Croatia). The tests were performed on raw, skimmed and skimmed bactofuged milk, and on pasteurized milk as a reference sample. Milk samples were aseptically taken into sterile vials at the sampling valves before the separator (raw milk), after the separator (skimmed milk), and after the bactofugation (skimmed bactofuged milk). As a reference control sample, pasteurized milk produced by the classical HTST (high-temperature short-time) process (processing parameters 72 °C/15 s) was taken.

Ultrasonic processing of milk samples

In this research, an ultrasonic processor model UP 400S (Dr. Hielscher GmbH, Teltow, Germany) was used. The characteristics of this ultrasonic processor are opened system with an effective output power 400 W, current voltage 230 V, 48-63 Hz, ultrasonic cycle 10–100%, ultrasonic frequency 24 kHz and amplitude 12-260 μm. A 7-mm diameter titanium probe was used in the work, and it was immersed at a depth of 2 cm in each milk sample.

Determination of milk somatic cell count

The count of somatic cells in milk, epithelial cells and leukocytes was determined by electronic cell counter (Fossomatic 5000; Foss Electric A/S, Hillerød, Denmark) using a cytometric method of fluoro-optoelectronic counting according to ISO 13366-2:2006 standard (12).

Determination of hygienic quality of milk

To determine the inactivation of the tested microorganisms before the treatment of the raw, skimmed and bactofuged milk samples, the initial number of tested microorganisms was determined. The reduction of the logarithmic number of microorganism cells after treatment was calculated according to the formula:

FTB-59-454-e1.jpg

where N0 is the total initial number of microorganisms before and N1 after the treatment.

Design of the experiment

The design of the experiment was marked with letters from A to D: (i) experiment A: Pultrasound=200 W, ν=24 kHz, t=20 °C, (ii) experiment B: Pultrasound=200 W, ν=24 kHz, t=55 °C, (iii) experiment C: Pultrasound=400 W, ν=24 kHz, t=20 °C, and (iv) experiment D: Pultrasound=400 W, ν=24 kHz, t=55 °C.

Treatments were performed at four different times (2.5, 5, 7.5 and 10 min). Raw, skimmed and bactofuged cow's milk were subjected to high-power ultrasound treatment of 200 and 400 W. Reductions of SCC, Enterobacteriaceae, E. coli and S. aureus were calculated. Each sample was analyzed three times and the presented results are the mean value of three measurements.

Preparation of samples

A volume of 1 mL of prepared decimal dilutions of samples was added to Petri dishes and poured over with a liquid nutrient medium. Furthermore, the samples were also inoculated on a prepared solid medium. A volume of 0.1 mL of a milk sample was added, and smeared with a Drigalsky stick. The samples were incubated according to the ISO 4833-1:2013 standard (13). Aerobic mesophilic bacteria were incubated at (30±1) °C for (72±2) h.

Incubation of Enterobacteriaceae was done at (37±1) °C for (24±2) h. Enterobacteriaceae were inoculated on a VRBG agar (crystal violet neutral red bille glucose agar, Merck, Darmstadt, Germany) and then coated with a cover layer of VRBG agar (15 mL) which, after solidification, prevented colony overgrowth and provided semi-anaerobic conditions (14).

Escherichia coli cells were analyzed on a TBX agar (tryptone bile X-glucuronide agar, Chromocult, Merck). Incubation was performed at (44±1) °C for (21±3) h (15).

S. aureus cells were confirmed by inoculating the samples on Baird-Parker agar (Merck) with the addition of egg yolk and tellurite emulsion. The cells were incubated at (37±1) °C for (24±2) h. When colonies appeared on the medium, they were confirmed by a positive catalase test. The test was performed using Bactident catalase reagent (Merck). The procedure was performed in such a way that a drop of reagent was added directly to a randomly selected colony on the medium. S. aureus colonies produce gas (16). If S. aureus colonies were not confirmed in the result section, they were indicated as not found (n.f.). If the count of S. aureus cells was less than 10 colonies, it was marked as <10, and if the number of cells was less than 100, it was marked as <100. The same was applied for the determination of Enterobacteriaceae and E. coli. If the number of cells was higher than 100, the exact number of colonies was specified.

Determination of the total viable count of bacteria

The total viable count (TVC) of bacteria was determined based on the number of counted colonies multiplied by the degree of dilution (17). Increased colonies were counted on a counter (colony counter, Kinesis Ltd, Saint Neots, UK), and the number of viable bacteria in the processed samples was expressed as the colony forming units (CFU). The number of units forming colonies was calculated according to the following formula and ISO 13366-2:2006 standard (12):

FTB-59-454-e2.jpg

Statistical data processing

Descriptive statistics was used to show mean values, standard deviation (S.D.), and minimum and maximum values for each experiment (18). In order to connect, i.e. determine the similarities and/or differences in a large data set for each observed characteristic or treatment, according to the experiment, multivariate statistical methods were applied (19). STATISTICA data analysis software v. 8 was used for data processing (20).

RESULTS AND DISCUSSION

The average values ​​of the somatic cell count (SCC) and their reduction in different experiments (A-D) are shown inTable 1. Lower count of somatic cells in untreated skimmed milk (SO) samples than in raw milk (RM) samples was observed. This is explained by the fact that the milk was collected in a centrifugal cream separator, and that part of the somatic cells ends up in the cream. To make it easier to monitor the impact of a treatment on the SCC, a reduction expressed in percentages was calculated. This means that the initial SCC from the reference sample of raw milk (RM) was used to recalculate the T1–T4 treatment reduction, and the skimmed milk (SO) sample was used to recalculate the T5–T12 treatment reduction. Considering the used bactofugation technique, the decrease of the somatic cell count in the reference sample of bactofuged skimmed milk (BSM) was noticeable in comparison with the reference sample of untreated skimmed milk (SO). Besides the fact that bactofugation removed 80-90% bacteria and 90-95% spores (1), it is evident that it also removes somatic cells.

Table 1 Influenece of different experimental conditions on the somatic cell count (SCC) in various milk samples and their reduction with time
SampleTreatment
ABCD
SCC/(cell/mL)SCCreduction/%SCC /(cell/mL)SCCreduction/%SCC/(cell/mL)SCCreduction/%SCC/(cell/mL)SCC reduction/%
RM320 0000365 0000278 0000347 0000
T1227 00029329 0001036 00087178 00049
T2132 00059280 0002319 00093110 00068
T3134 00058130 0006417 0009454 00084
T484 00074160 0005614 0009563 00082
SO262 0000192 0000264 0000201 0000
T5130 00050120 00038119 00055140 00030
T650 0008195 0005167 00075106 00047
T737 0008684 0005637 0008668 00066
T821 0009276 0006021 0009224 00088
BSM19 0009317 000919 0009724 00088
T911 0009616 000927 0009710 00095
T108 0009712 000944 000987 00097
T116 0009810 000952 000994 00098
T124 000988 000962 000993 00099
PM22 0009224 000887 0009718 00091

Experiments A and B: P=200 W, ν=24 Hz, t=20 and 55 °C, respectively. Experiments C and D: P=400 W, ν=24 Hz, t=20 and 55 °C, respectively. Reference samples for calculating the reduction of SCC: RMF=raw milk, SO=untreated skimmed milk, BSM=bactofuged skimmed milk, PM=pasteurized milk. T1–T4=raw milk, T5–T8=skimmed milk and T9–T12=bactofuged skimmed milk treated for 2.5, 5, 7.5 and 10 min

Experiments A-D have shown that high-power ultrasound, regardless of temperature used in the treatment, reduces the somatic cell count by creating high local temperature and pressure that cause cell wall rupture and cell disintegration (21,22). In all experiments, it was observed that the reduction of SCC was higher in ultrasound-treated samples (even at 2.5 min) than in pasteurized samples (in the pasteurization process, bactofugation was included as part of the process (Fig. 1a)). This is in agreement with the findings of Povey and Mason (23) and Cameron (24), who reported that ultrasound treatment of milk significantly reduces the count of somatic cells. However, reduction of somatic cell count did not improve milk quality due to high initial number of somatic cells.

Fig. 1 Principal component analysis of somatic cell distribution (SCC), and their reduction: a) without rotation, and b) after Verimax rotation. Experiments A and B: P=200 W, ν=24 Hz, t=20 and 55 °C, respectively. Experiments C and D: P=400 W, ν=24 Hz, t=20 and 55 °C, respectively. Reference samples: RM=raw milk, SO=untreated skimmed milk, BSM=bactofuged skimmed milk, PM=pasteurized milk. T1–T4=raw milk, T5–T8=skimmed milk and T9–T12=bactofuged skimmed milk treated for 2.5, 5, 7.5 and 10 min
FTB-59-454-f1

For each experiment, the observed relationship of the pooled data (Fig. 1) with the corresponding Pearson correlation matrix (Table 2) is shown. The results show the expected negative correlation between the somatic cell count and their reduction, which implies their inversely proportional relationship depending on the experimental conditions (A-D). Grouping of bactofuged samples was seen in all experiments; inFig. 1a in the first and inFig. 1b in the fourth quadrant. The analysis of the main components of the somatic cell count distribution and its reduction before rotation is shown inFig. 1a. Treated milk samples (T8–T12, BSM and PM) were grouped on the right side of the plot, representing samples in which significantly higher reduction of SCC was achieved than in the samples located on the left side of the plot (T1–T7, RM and SO). Bactofuged samples (T9–T12, BSM and PM) were positioned in the first quadrant and correlated with the results of SCC reduction from all experiments (A-D; 1st and 4th quadrant). The contribution of the first and second components is also important (F1=80.05%, F2=13.62%), and the dominance of the first component is visible. Precisely for this reason, rotation was used to distribute the influence of the principal components. Verimax rotation, which is often used in the food industry, was applied and the results are shown inFig. 1b. It was observed that the share of variations explained in this data set after the rotation remains the same with a high 93.67%, and the bactofugated samples, as shown inFig. 1b, grouped separately, but now the reduction data of SCC in different experiments no longer spread through the 1st and 4th quadrants. They were grouped only in the 4th quadrant, and the SCC, depending on the experiments, was grouped in the 2nd quadrant. As expected, the ratio of SCC in the milk and its reduction was inversely proportional (Fig. 1b). The first main component explains the high 48% variation in the SCC and its reduction in experiments A, C and D with better reduction results, while the second main component explains the variations in less successful experiments B in terms of total SCC reduction (T1–T12, SO, BSM and PM).

Table 2 Pearson correlation matrix for somatic cell count (SCC) and its reduction, depending on the treatment, with a significance level of 5%
ObservedSCC/(cell/mL) (_s)SCCreduction/% (_r)
A_sB_sC_sD_sA_rB_rC_rD_r
A_s1.000.900.820.94-0.99-0.92-0.81-0.87
B_s0.901.000.580.87-0.85-0.92-0.57-0.72
C_s0.820.581.000.88-0.86-0.75-1.00-0.93
D_s0.940.870.881.00-0.93-0.90-0.87-0.93
A_r-0.99-0.85-0.86-0.931.000.920.860.91
B_r-0.92-0.92-0.75-0.900.921.000.750.89
C_r-0.81-0.57-1.00-0.870.860.751.000.93
D_r-0.87-0.72-0.93-0.930.910.890.931.00

Experiments A and B: P=200 W, ν=24 Hz, t=20 and 55 °C, respectively. Experiments C and D: P=400 W, ν=24 Hz, t=20 and 55 °C, respectively. _s=somatic cells, _r=reduction of somatic cells

Correspondence analysis (CA) is a method of data visualization that is applicable to contingency tables (25). It was performed with the aim of comparing differently treated samples in different experiments and the efficiency of SCC reduction.Table 3 shows the change in the SCC, its significance and representation in the first two factors (F1 and F2). In a bactofuged sample treated for 10 min (T12), the SCC count ranged from 2000, in experiment C, to 8000 cell/mL, in experiment B. InTable 3, when observing SCC, there are two columns showing the representation in the reduced number of factors (reduced to two, i.e. F1 and F2) and the RM sample dominates in the factor F1, and T1 and T2 in the second factor, F2. Their dominance in factor F2 was associated with a high somatic cell count.

Table 3 Reduction of somatic cell count (SCC), its significance and representation in the first two factors for different treatments
Milk sampleSCC/(cell/mL)SCCreduction/%
Significant orderF1F2Significant orderF1F2
RM10.2750.010150.0000.000
T130.0010.283140.0980.521
T240.0430.162120.1050.123
T370.0500.01770.0290.007
T460.1010.01090.0730.001
SO20.2300.097150.0000.000
T550.0130.071130.0290.052
T680.0170.099110.0790.148
T790.0750.105100.0890.084
T8100.1730.12480.1180.062
BSM120.0110.00450.0680.000
T9130.0010.00140.0640.000
T10140.0000.00230.0640.000
T11150.0010.00120.0620.000
T12160.0040.00110.0610.000
PM110.0030.01260.0630.003

Reference samples for calculating the reduction of SCC: RM=raw milk, SO=untreated skimmed milk, BSM=bactofuged skimmed milk, PM=pasteurized milk. T1–T4=raw milk, T5–T8=skimmed milk and T9–T12=bactofuged skimmed milk treated for 2.5, 5, 7.5 and 10 min

The antimicrobial effect of ultrasound is achieved by cavitation, i.e. extremely rapid formation and collapse of bubbles formed in the medium by the action of ultrasonic waves. This effect occurrs due to changes in pressure and temperature, which cause cell wall rupture and thinning of the cell membrane (22,26,27). Also, due to the action of free radicals, DNA damage can occur.Table 4 shows the total viable count (TVC) of bacteria and the reduction of their logarithmic number (LNC) in milk samples according to different conditions of experiments A–D. Analysis of LNC reductions within the same experiment (regardless of power, frequency and temperature parameters) shows that the best results were achieved by ultrasound treatment of bactofuged skimmed milk samples in the follwing order: experiment D (reduction of LNC from T9=2.31 to T12=2.68), experiment B (reduction from T9=2.14 to T11=2.44), experiment C (reduction from T12=2.06 to T9/10=2.20) and experiment A (reduction from T10=1.94 to T12=2.04). From the analyzed data, it can be concluded that better results of TVC reduction were observed in experiments D (P=400 W, t=55 °C) and B (P=200 W, t=55 °C), in which milk was treated by high-power ultrasound. Cameron (24) stated that in order to achieve better results for the inactivation of microorganisms in milk, it is recommended to combine high-power ultrasound with slightly elevated temperature, which we confirmed in this work. Many other authors discussed that the inactivation of microorganisms exposed to the combination of ultrasound and temperature is much higher, which is consistent with the results of this work (28,29). According the regulations from the Rules on microbiological criteria (30) (m=103 CFU/mL, M=104 CFU/mL, n=5, c=1, where m is the limit value below which all results are considered satisfactory, and M is the limit value above which the results are considered unsatisfactory), only the results of the number of bacteria in bactofuged samples of A–D experiments and pasteurized milk reference samples (PM) proved to be satisfactory.Table 5 shows the contribution of experiments A–D, their significance and representation in the first two factors for the changes in total number of bacteria (CFU/mL).

Table 4 Influence of different experimental treatments on total number of bacteria and reduction of logarithmic number in milk samples
Milk sampleTreatment
ABCD
TVCLNCLNCreductionTVCLNCLNCreductionTVCLNCLCreductionTVCLNCLNCreduction
CFU/mLlog
CFU/mL
CFU/mLlog CFU/mLCFU/mLlog CFU/mLCFU/mLlog CFU/mL
RM450 0005.650.001 050 0006.020.00400 0005.600.00580 0005.760
T1110 0005.040.61142 0005.150.8772 0004.860.7531 0004.491.27
T257 6004.760.89126 0005.100.9240 0004.601.0018 0004.261.51
T348 0004.680.9724 0004.381.6425 0004.401.204 0003.602.16
T476 8004.890.7716 0004.201.8244 0004.640.965 0003.702.06
SO438 0005.640.00656 0005.820.00160 0005.200.00408 0005.610.00
T569 0004.840.80100 0005.000.8232 0004.510.7078 0004.890.72
T6100 0005.000.64120 0005.080.7423 0004.360.8458 0004.760.85
T796 0004.980.66140 0005.150.6729 0004.460.7460 0004.780.83
T862 0004.790.8529 0004.461.3620 0004.300.908 8003.941.67
BSM11 0004.041.6017 8004.251.574 0803.611.5911 0004.041.57
T94 5603.661.984 8003.682.141 0003.002.202 0003.302.31
T105 0003.701.944 2003.622.191 0003.002.201 1003.042.57
T114 1603.622.022 4003.382.441 2003.082.131 3003.112.50
T124 0003.602.042 6003.422.041 4003.152.068602.932.68
PM3362.533.1210023.821002.003.209202.962.65

Experiments A and B: P=200 W, ν=24 Hz, t=20 and 55 °C, respectively. Experiments C and D: P=400 W, ν=24 Hz, t=20 and 55 °C, respectively. Reference samples for calculating the reduction of bacterial count: RM=raw milk, SO=untreated skimmed milk, BSM=bactofuged skimmed milk, PM=pasteurized milk. T1–T4=raw milk, T5–T8=skimmed milk and T9–T12=bactofuged skimmed milk treated for 2.5, 5, 7.5 and 10 min. TVC=total viable count of bacteria, LNC=logarithm of total count of bacteria

Table 5 Contribution of experiments A-D, their significance and representation in the first two factors for the changes in total number of bacteria
ExperimentSignificanceF1F2
A40.0010.031
B30.3390.013
C60.0310.235
D50.2720.059

Experiments A and B: P=200 W, ν=24 Hz, t=20 and 55 °C, respectively. Experiments C and D: P=400 W, ν=24 Hz, t=20 and 55 °C, respectively

In accordance with the first part of Singh and Heldman's assumption (31), the combination of ultrasound and heat should result in a product with a longer shelf life, and the required processing time could even be reduced, leading to lower production cost. The main problem here, however, is the required processing time with ultrasound, which is much longer than the classical pasteurization method (7.5–10 min versus 0.25 min). One of the possibilities to solve this problem is to install ultrasonic probes in the process after bactofugation.

Herceg et al. (32) noted that the system of high-power ultrasound processing of milk in industrial production should be designed to allow maximum contact between the milk and the cavitation zone, and that it would be useful to explore the possibility of using multiple ultrasound probes. The action of a parallel series of ultrasound probes should be further demonstrated and confirmed. This would be in line with the suggestion by Ashokkumar et al. (33), who explained that in the dairy industry, it would be interesting to add ultrasound as a new process function to improve the functionality of the products. Furthermore, Oliveira and Oliveirana (34) represented in their work that higher inactivation of microorganisms was obtained when using the sonication technique at 70 °C. Results achieved by Sala et al. (35) in the inactivation of microorganisms using thermal sonication of milk at 70 °C, which is also used in standard high-temperature short-time pasteurization (HTST) procedure, showed high reduction results. They consider that milk treated in this way would not contain vegetative cells, and that it would have a longer shelf life with minimal processing. Furthermore, the product could be similar, in terms of microorganism content, to ultra-high temperature (UHT) milk.

It is prescribed that the number of Enterobacteriaceae must be within the following limits m=M≤10 CFU/mL for the sample to be considered satisfactory. In the results shown inTable 6, it was observed that high-power ultrasound treatment of milk gives good results of Enterobacteriaceae inactivation. Satisfactory results of the treatment of raw milk T1–T4 samples were observed in high-power ultrasound experiments B and D, where the power was 200 and 400 W, respectively, combined with an elevated temperature of 55 °C. The same trend was observed in the samples T5–T8 of the same experiments (B and D), and F.

Table 6 Influence of treatments on total number of Enterobacteriaceae and number of Escherichia coli cells
Milk sampleTreatment
ABCDABCD
N(Enterobacteriaceae)/(CFU/mL)N(Escherichia coli)/(CFU/mL)
RM900510200910500390210730
T184010140<104101090<10
T2720<10110<10100<10100<10
T31 000<10140<10500<1050<10
T4360<10160<10<100<1020<10
SO200200130620180110100100
T5100n.n.<100<10100<10<100<10
T6<100<10<100<10<100<10<100<10
T7<100<10<100<10100<10<100<10
T8<100<10<100<10<100<10<100<10
BSM<10<101520<10<101310
T9<10<1010<10<10<1010<10
T10<10<1010<10<10<1010<10
T11<10<10<10<10<10<10<10<10
T12<10<1010<10<10<1010<10
PM<10<10<10<10<10<10<10<10

Experiments A and B: P=200 W, ν=24 Hz, t=20 and 55 °C, respectively. Experiments C and D: P=400 W, ν=24 Hz, t=20 and 55 °C, respectively. Reference samples: RM=raw milk, SO=untreated skimmed milk, BSM=bactofuged skimmed milk, PM=pasteurized milk. T1–T4=raw milk, T5–T8=skimmed milk and T9–T12=bactofuged skimmed milk treated for 2.5, 5, 7.5 and 10 min

The number of Escherichia coli in milk (Table 6) was also observed. Cameron et al. (24) suggested that ultrasound cavitation destroys the cells of undesirable contaminants such as E. coli bacteria, which is confirmed by the results in this work. As with Enterobacteriaceae, satisfactory results of treatment of raw milk T1–T4 samples were observed in high-power ultrasound treated samples in experiments B and D, and in samples F2 (5 min) and F4 (10 min). The same trend was observed in samples T5–T8 in experiments B and D.

Table 7 shows the results of Staphylococcus aureus inactivation in all experiments, with satisfactory results of T1–T4 whole milk treatments in all high-power ultrasound samples of experiments B, D and F. The same trend is seen in high-power ultrasound samples T5–T8 in experiments B and D. In all experiments with reference samples BSM and PM, and treatments T9–T12, it was observed that the S. aureus number met the criterion M=10 CFU/mL. It can be seen that in samples B9/10, D9/10, F9–F12 and P (experiments B and D) the presence of bacteria was not proven/found (n.f.), which means that these samples were additionally investigated to confirm the presence of S. aureus species. Oliveira and Oliveirana (34) investigated the inactivation of S. aureus cells by high-power ultrasound treatment and concluded that higher inactivation was obtained when using a combination of ultrasound with slightly elevated temperature than when using only ultrasound for inactivation, which is in accordance with the results obtained in this work. Sherba et al. (36) studied the effect of ultrasound (24 kHz) on S. aureus species and concluded that it has a bactericidal effect, and that inactivation of this bacteria increases with time and intensity of ultrasound. Thus, the reduction of S. aureus in their work increased from 22 to 39% with an increase in the intensity from 1 to 3 for 15 min, or with an extension of the ultrasound time (2-30 min, 3 W/cm2), the reduction was 42-43%.

Table 7 Influence of treatments on total number of Staphylococcus aureus cells
Milk sampleTreatment
ABCD
N(Staphylococcus aureus)/(CFU/mL)
RM200350150100
T116010180<10
T2170n.f.120<10
T3110<10120<10
T4140<10110<10
SO120130<100100
T5<100n.f.<100<10
T6<100n.f.<100n.f.
T7<100<10100<10
T8<100<10<100<10
BSM<10<10<10<10
T910n.f.<10n.f.
T10<10n.f.<10n.f.
T11<10<10<10<10
T12<10<10<10<10
PM<10n.f.<10n.f.

Experiments A and B: P=200 W, ν=24 Hz, t=20 and 55 °C, respectively. Experiments C and D: P=400 W, ν=24 Hz, t=20 and 55 °C, respectively. Reference samples: RM=raw milk, SO=untreated skimmed milk, BSM=bactofuged skimmed milk, PM=pasteurized milk. n.f.=not found. T1–T4=raw milk, T5–T8=skimmed milk and T9–T12=bactofuged skimmed milk treated for 2.5, 5, 7.5 and 10 min

CONCLUSIONS

This work deals with the possibility of processing raw and skimmed cow's milk using high-power ultrasound in combination with slightly elevated temperature and pretreatment with bactofugation in order to achieve microbiological safety of milk. This is accomplished by optimizing the processes of bactofugation, ultrasound treatment (frequency 24 kHz and power 400 W) and slightly elevated temperatures, up to 55 °C, with the emphasis on the microbiological quality of milk, in accordance with legislation (somatic cell count in 1 mL must be ≤400 000). In bactofuged milk processed by high-power ultrasound, high inactivation of the total number of bacteria (from 1.61 to 1.77 log CFU/mL) was observed. The findings suggest that there is a possible application of new technologies in food processing as an effective replacement for thermal treatment; thus bactofugation in combination with high-power ultrasound could be an alternative to pasteurization.

Notes

[1] Financial disclosure FUNDING

This study was funded by the Republic of Croatia, Ministry of Science and Education through the European Regional Development Fund, project KK.01.1.1.02.0001: ’Equipping the semi-industrial practice for the development of new food technologies’.

ACKNOWLEDGEMENTS

This study was conducted in the Center for the Development of Innovative Food Processing Techniques, Faculty of Food Technology and Biotechnology, Zagreb, Croatia.

Notes

[2] Conflicts of interest CONFLICT OF INTEREST

The authors declare no conflict of interest.

REFERENCES

1 

Tratnik Lj, Božanić R, editors. Milk and diary product. Zagreb, Croatia: Croatian Dairy Association; 2012 (in Croatian).

2 

Muehlhoff E, Bennett A, McMahon D. Milk, editors. Milk and dairy products in human nutrition. Rome, Italy: Food and Agriculture Organization of the United Nations(FAO); 2013.

3 

Rules on determination of raw milk composition NN 27/2017. Zagreb, Croatia: Official Gazzete of the Republic of Croatia; 2017. Available from:https://narodne-novine.nn.hr/clanci/sluzbeni/2017_03_27_613.html (in Croatian).

4 

Code of hygienic practice for milk and milk products (CAC-RCP57-2004). Geneva, Switzerland: Food and Agriculture Organization of the United Nations and World Health Organization (FAO/WHO); 2012. Available from:https://www.fao.org/fileadmin/user_upload/livestockgov/documents/CXP_057e.pdf.

5 

Ribeiro JC, Peruzi GAS, Bruzaroski SR, Tamanini R, Lobo CM, Alexandrino B, et al. Short communication: Effect of bactofugation of raw milk on counts and microbial diversity of psychrotrophs. J Dairy Sci. 2019;102(9):7794–9. https://doi.org/10.3168/jds.2018-16148 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/31279557

6 

Salve AR, Pegu K, Arya SS. Comparative assessment of high-intensity ultrasound and hydrodynamic cavitation processing on physico-chemical properties and microbial inactivation of peanut milk. Ultrason Sonochem. 2019;59:104728. https://doi.org/10.1016/j.ultsonch.2019.104728 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/31421619

7 

Herceg Z, Juraga E, Sobota Šalamon B, Režek Jambrak A. Inactivation of mesophilic bacteria in milk by means of high intensity ultrasound using response surface methodology. Czech J Food Sci. 2012;30:108–17. https://doi.org/10.17221/93/2011-CJFS

8 

Leong TSH, Zhou M, Zhou D, Ashokkumar M, Martin GJO. The formation of double emulsions in skim milk using minimal food-grade emulsifiers–A comparison between ultrasonic and high pressure homogenisation efficiencies. J Food Eng. 2018;219:81–92. https://doi.org/10.1016/j.jfoodeng.2017.09.018

9 

Juraga E, Sobota Šalamon B, Herceg Z, Režek Jambrak A. Application of high intensity ultrasound treatment on Enterobacteriae count in milk. Mljekarstvo. 2011;61(2):125–34.

10 

Dai J, Bai M, Li C, Cui H, Lin L. Advances in the mechanism of different antibacterial strategies based on ultrasound technique for controlling bacterial contamination in food industry. Trends Food Sci Technol. 2020;105:211–22. https://doi.org/10.1016/j.tifs.2020.09.016

11 

Huang G, Chen S, Dai C, Sun L, Sun W, Tang Y, et al. Effects of ultrasound on microbial growth and enzyme activity. Ultrason Sonochem. 2017;37:144–9. https://doi.org/10.1016/j.ultsonch.2016.12.018 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/28427617

12 

ISO 13366-2:2006. Determination of somatic cell count-fluoro-opto-electronic method. Geneva, Switzerland: International Organization for Standardization (ISO); 2006 (in Croatian).

13 

ISO 4833-1:2013. Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 1: Colony count at 30 °C by the pour plate technique. Geneva, Switzerland: International Organization for Standardization (ISO); 2013 (in Croatian).

14 

ISO 21528-2:2008. Microbiology of food and animal feeding stuffs - Horizontal methods for the detection and enumeration of Enterobacteriaceae - Part 2: Colony-count method. Geneva, Switzerland: International Organization for Standardization (ISO); 2008 (in Croatian).

15 

ISO 16649-2:2001. Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli - Part 2: Colony-count technique at 44 degrees C using 5-bromo-4-chloro-3-indolyl beta D-glucuronide. Geneva, Switzerland: International Organization for Standardization (ISO); 2001 (in Croatian).

16 

ISO 6888-1:2004. Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of coagulase-positive staphylococci (Staphylococcus aureus and other species) -Part 1: Technique using Baird-Parker agar medium. Geneva, Switzerland: International Organization for Standardization (ISO); 2004 (in Croatian).

17 

Duraković S. Food microbiology. Zagreb, Croatia: Medicinska naklada; 1991. pp. 135-7 (in Croatian).

18 

Bahovec V, Erjavec N. Statistics. Zagreb, Croatia: Element plc; 2015 (in Croatian).

19 

Kurtanjek Ž, Gajdoš-Kljusurić J. Statistical modelling of anthropometric characteristics evaluated on nutritional status. In: Granato D, Ares G, editors. Mathematical and statistical methods in food science and technology. Oxford, UK: John Wiley and Sons; 2014. pp. 285-302.

20 

STATISTICA, v. 8.0., StatSoft, Inc., Tulsa, OK, USA; 2007. Available from:www.statsoft.com.

21 

Koseki S, Yamamoto K. A novel approach to predicting microbial inactivation kinetics during high pressure processing. Int J Food Microbiol. 2007;116(2):275–82. https://doi.org/10.1016/j.ijfoodmicro.2007.01.008 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/17363099

22 

Akdeniz V, Akalın AS. Recent advances in dual effect of power ultrasound to microorganisms in dairy industry: Activation or inactivation. Crit Rev Food Sci Nutr. 2020;1–16. https://doi.org/10.1080/10408398.2020.1830027 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/33030040

23 

Povey MJW, Mason TJ. Ultrasound in food processing. London, UK: Blackie Academic & Professional; 1998. pp.103-26.

24 

Cameron M. Impact of low-frequency high-power ultrasound on spoilage and potentially pathogenic dairy microbes [PhD thesis]. Stellenbosch, South Africa: University of Stellenbosch; 2007.

25 

Greenacre M. Correspondence analysis in practice. New York, NY, USA: Chapman and Hall/CRC, Taylor & Francis Group; 2007.

26 

Manvell C. Minimal processing of food. Food Sci Technol Today. 1997;11:107–11.

27 

Ross AIV, Griffiths MW, Mittal GS, Deeth HC. Combining nonthermal technologies to control foodborne microorganismus. Int J Food Microbiol. 2003;89(2-3):125–38. https://doi.org/10.1016/S0168-1605(03)00161-2 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/14623378

28 

Fan L, Hou F, Muhammad AI, Ruiling LV, Watharkar RB, Guo M, et al. Synergistic inactivation and mechanism of thermal and ultrasound treatments against Bacillus subtilis spores. Food Res Int. 2019;116:1094–102. https://doi.org/10.1016/j.foodres.2018.09.052 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/30716893

29 

Li J, Suo Y, Liao X, Ahn J, Liu D, Che S, et al. Analysis of Staphylococcus aureus cell viability, sublethal injury and death induced by synergistic combination of ultrasound and mild heat. Ultrason Sonochem. 2017;39:101–10. https://doi.org/10.1016/j.ultsonch.2017.04.019 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/28732925

30 

Rules on microbiological criteria for food NN 74/2008. Zagreb, Croatia: Official Gazzete of the Republic of Croatia; 2008 (in Croatian). Available from:https://narodne-novine.nn.hr/clanci/sluzbeni/full/2008_06_74_2454.html.

31 

Singh RP, Heldman DR. Introduction of food engineering. New York, NY, USA: Academic Press; 2001.

32 

Herceg Z, Brnčić M, Režek Jambrak A, Rimac Brnčić S, Badanjak M, Sokolić I. Possibility of application high intensity ultrasound in milk industry. Mljekarstvo. 2009;59(1):65–9. [in Croatian]

33 

Ashokkumar M, Bhaskaracharya R, Kentish S, Lee J, Palmer M, Zisu B. The ultrasonic processing of dairy products: An overview. Dairy Sci Technol. 2010;90(2-3):147–68. https://doi.org/10.1051/dst/2009044

34 

Oliveira FAR, Oliveirana JC. Processing foods. Boca Raton, FL, USA: CRC Press; 1999.

35 

Sala FJ, Burgos J, Condón S, Lopez P, Raso J. Effect of heat and ultrasound on microorganisms and enzymes. In: Gould FW, editor. New methods of food preservation. London, UK: Blackie Academic & Professional; 1995. pp. 176-204.

36 

Scherba G, Weigel RM, O’Brien WD. Quantitative assessment of the germicidial efficacy of ultrasonic energy. Appl Environ Microbiol. 1991;57(7):2079–84. https://doi.org/10.1128/aem.57.7.2079-2084.1991 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/1892396


This display is generated from NISO JATS XML with jats-html.xsl. The XSLT engine is libxslt.