Skip to the main content

Original scientific paper

Insulation Verification Using Low Voltage and High Current Sensitivity

Tonko Garma orcid id orcid.org/0000-0001-9712-1084 ; Walter Schottky Institute, Techical University of Munich
Željka Milanović ; Faculty of Engineering, University of Rijeka
Ivan Marasović ; Faculty of Electrical Engineering, Mechanical Engineering and Naval Architecture, University of Split


Full text: english pdf 283 Kb

page 86-95

downloads: 1.640

cite


Abstract

The classic approach for determining insulating resistance by using commercial testers is not reliable for testing different types of insulation, especially for cables with one conductor and nanoelectronic oxide-based devices (nanotransistors). In this paper an alternative low-voltage method for measuring insulation resistance based on strongly increased current sensitivity is proposed. The proposed method of measuring insulation resistance at low voltages is realized by using a high sensitivity Keithley SMU 2612 unit. The verification of the proposed method is made by measuring insulation resistance of medical Corkscrew Electrode and gate oxide resistance for nano-scaled MOSFET. Finally, results of measuring insulation resistance obtained by commercial testers and proposed method in the verification process are compared.

Keywords

Commercial insulation testers; Insulation resistance measuring methods; Low-voltage resistance measuring method; Nano-transistor gate-oxide resistance

Hrčak ID:

84222

URI

https://hrcak.srce.hr/84222

Publication date:

18.6.2012.

Visits: 2.433 *