Skip to the main content

Preliminary communication

https://doi.org/10.14256/JCE.2168.2017

Shear breakout capacity of various fastening systems in concrete elements

Natalija Bede
Philipp Grosser
Joško Ožbolt


Full text: croatian pdf 541 Kb

page 1093-1100

downloads: 1.657

cite

Full text: english pdf 542 Kb

page 1093-1100

downloads: 1.261

cite


Abstract

The results of a test program carried out to investigate the difference in the concrete breakout capacity of various fastening systems installed parallel to the edge of a concrete member, and loaded in shear towards the edge of the concrete member, are presented and analysed. According to the current design recommendations, the calculated concrete breakout capacity of anchor channels yields to a lower failure capacity compared to headed anchors. Welded anchors (headed anchors welded to a steel plate) and bonded anchors are also tested. Based on the test results, various fastening systems in concrete elements are compared.

Keywords

fastening systems; failure due to concrete fracturing; shear load; experimental testing; design recommendations

Hrčak ID:

192785

URI

https://hrcak.srce.hr/192785

Publication date:

23.1.2018.

Article data in other languages: croatian

Visits: 3.543 *