Skip to the main content

Original scientific paper

Contamination source detection in water distribution networks

Lado Kranjčević ; Faculty of Engineering University of Rijeka
Marko Čavrak ; Faculty of Engineering University of Rijeka
Marko Šestan ; Faculty of Engineering University of Rijeka


Full text: croatian pdf 845 Kb

page 11-25

downloads: 630

cite

Full text: english pdf 845 Kb

page 11-25

downloads: 1.081

cite


Abstract

The numerical hydraulic simulation of pipe networks calculates the heads and discharges at the inner points of pipes and other non-pipe elements of the network. Besides these calculations, contaminant and solutes spreading in the pipe network can be of interest, too. The contamination spreading through the water-distribution pipe networks is controlled mainly by mixing properties at pipe junctions. Real mixing that can occur within a pipe junction lies between the complete-mixing model and incomplete-mixing model assumptions. In this paper, we demonstrate the inverse modeling in trying to detect the source of contamination within the pipe network. We assume a scenario where contaminant concentrations are measured in one, two or more nodes of the pipe network. These results are used as a starting point for the inverse source detecting procedure. The inverse source detection procedure is shown and verified on an experimental model.

Keywords

pipe network; incomplete mixing; contaminant dispersion; inverse source detection

Hrčak ID:

63635

URI

https://hrcak.srce.hr/63635

Publication date:

23.12.2010.

Article data in other languages: croatian

Visits: 3.018 *