Skoči na glavni sadržaj

Izvorni znanstveni članak

Effect of High Intensity Ultrasound and Pasteurization on Anthocyanin Content in Strawberry Juice

Igor Dubrović ; Nastavni Zavod za javno zdravstvo Primorsko-goranske županije, Krešimirova 52a, HR-51000 Rijeka, Hrvatska
Zoran Herceg orcid id orcid.org/0000-0003-3967-6676 ; Prehrambeno-biotehnološki fakultet, Sveučilište u Zagrebu, Pierottijeva 6, HR-10000 Zagreb, Hrvatska
Anet Režek Jambrak ; Prehrambeno-biotehnološki fakultet, Sveučilište u Zagrebu, Pierottijeva 6, HR-10000 Zagreb, Hrvatska
Marija Badanjak ; Prehrambeno-biotehnološki fakultet, Sveučilište u Zagrebu, Pierottijeva 6, HR-10000 Zagreb, Hrvatska
Verica Dragović-Uzelac ; Prehrambeno-biotehnološki fakultet, Sveučilište u Zagrebu, Pierottijeva 6, HR-10000 Zagreb, Hrvatska


Puni tekst: engleski pdf 175 Kb

str. 196-204

preuzimanja: 2.258

citiraj


Sažetak

The purpose of this investigation is to study the influence of high intensity ultrasound and pasteurization on the stability of anthocyanins and their content in strawberry juice. Different ultrasound process parameters for the treatment of juices are compared to the classical thermal treatments. For ultrasound treatments, three parameters were varied according to the statistical experimental design. Central composite design was used to optimize and design experimental parameters: temperature (25, 40 and 55 °C), amplitude (60, 90 and 120 μm) and time (3, 6, and 9 min). It was found that the anthocyanin content after pasteurization (85 °C for 2 min) was reduced by 5.3 to 5.8 % compared to untreated juices. After treatment with ultrasound (20 °C for 3, 6 or 9 min) or thermosonication (40 °C for 3, 6 or 9 min and 60 °C for 3 or 6 min), the degradation of anthocyanins was generally less intensive and was 0.7–4.4 % compared to the untreated juices. Only in the case of ultrasonic treatment at a temperature of 55 °C and treatment time of 9 min the total content of anthocyanins, compared to untreated juice, was reduced by 5.8 to 7.1 %, and their degradation was greater than that of pasteurized juices. From the results it can be concluded that total anthocyanin content was greater in more than 85 % of the selected ultrasound treatments compared to pasteurized juices. Ultrasound treatment can replace pasteurization in terms of preserving total anthocyanin content. The modelling approaches using response surface methodology (RSM) developed in this study exploit data in order to identify the optimal processing parameters for lowering degradation of anthocyanins in strawberry juice during ultrasound processing.

Ključne riječi

high intensity ultrasound; anthocyanins; strawberry juice; response surface methodology

Hrčak ID:

69461

URI

https://hrcak.srce.hr/69461

Datum izdavanja:

15.6.2011.

Podaci na drugim jezicima: hrvatski

Posjeta: 4.217 *