Skoči na glavni sadržaj

Izvorni znanstveni članak

Ion nitriding using active screen method

M. Ogorek ; Czestochowa University of Technology, Faculty of Materials Processing Technology and Applied Physics, Czestochowa, Poland
T. Frączek ; Czestochowa University of Technology, Faculty of Materials Processing Technology and Applied Physics, Czestochowa, Poland


Puni tekst: engleski pdf 734 Kb

str. 243-246

preuzimanja: 494

citiraj


Sažetak

Austenitic steel grade 304 according to AISI was tested after ion nitriding in the temperature range 325 - 400 °C and time range 2 - 4 h, and after two different variants of sample arrangement in a glow discharge chamber. The first variant – the samples intended for nitriding were placed on the cathode, the second variant – the samples placed on the cathode were shielded with an active screen. In order to evaluate the effectiveness of the nitriding process variants, investigations of the diffusion depth of the obtained surface layers, surface hardness tests and tribological wear tests were carried out. It was found that using active screens increases the rate of diffusion of nitrogen into nitrided austenitic steel 304, thus increasing the thickness of the resulting surface layers.

Ključne riječi

austenitic steel; ion nitriding; diffusion; microhardness; abrasion; active screen method

Hrčak ID:

218391

URI

https://hrcak.srce.hr/218391

Datum izdavanja:

1.7.2019.

Posjeta: 1.227 *