Metallurgy, Vol. 60 No. 1-2, 2021.
Original scientific paper
Corrosion fatigue crack propagation of AISI 316L by nitrogen ion implantation in simulated body fluid
E. U. K. Maliwemu
; Department of Mechanical and Industrial Engineering, Universitas Gadjah Mada, Grafika No. 2, Yogyakarta, Indonesia; Department of Mechanical Engineering, Universitas Nusa Cendana, Adisucipto, Penfui, Kupang, NTT, Indonesia
V. Malau
orcid.org/0000-0003-3561-0688
; Department of Mechanical and Industrial Engineering, Universitas Gadjah Mada, Grafika No. 2, Yogyakarta, Indonesia
P. T. Iswanto
; Department of Mechanical and Industrial Engineering, Universitas Gadjah Mada, Grafika No. 2, Yogyakarta, Indonesia
I. Kambali
; National Nuclear Energy Agency, Babarsari, Yogyakarta, Indonesia
T. Sujitno
; National Nuclear Energy Agency, Babarsari, Yogyakarta, Indonesia
Suprapto
; National Nuclear Energy Agency, Babarsari, Yogyakarta, Indonesia
Abstract
A thin layer was formed on the surface of the AISI 316L substrate by the process of nitrogen ion implantation at a vacuum pressure of 10-6 torr, a current of 50 mA for 90 minutes with the implantation energy of 20, 40 and 60 keV. The purpose of this study was to investigate the effect of nitrogen ion implantation on corrosion fatigue resistance in Simulated Body Fluid solution as a corrosion medium. The results show that the nitrogen ion implantation could increase corrosion resistance by reducing the corrosion rate and increasing the number of fatigue cycles.
Keywords
AISI 316L; corrosion; fatigue; nitrogen ion implantation; simulated body fluid
Hrčak ID:
246085
URI
Publication date:
4.1.2021.
Visits: 1.358 *