Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.17559/TV-20200610115005

Impact Assessment of the Power Line Channel Characteristics in Real Topology

Dženana Tomašević* orcid id orcid.org/0000-0002-0957-054X ; University of Sarajevo, Faculty of Electrical Engineering, Zmaja od Bosne bb, 71 000 Sarajevo E-mail: dzenana.tomasevic@etf.unsa.ba
Tatjana Konjić orcid id orcid.org/0000-0002-6229-4548 ; University of Tuzla, Faculty of Electrical Engineering, Franjevačka 2, 75 000 Tuzla
Suad Kasapović ; University of Tuzla, Faculty of Electrical Engineering, Franjevačka 2, 75 000 Tuzla


Puni tekst: engleski pdf 1.074 Kb

str. 386-394

preuzimanja: 451

citiraj


Sažetak

This paper investigates the effect of different parameters of power line topology on PLC system. Information about real radial power distribution network is used to define a PLC channel model in NS-3 simulator. The overhead LV distribution network was modelled in the extended bandwidth. Results of real measurements are linked with simulation results in order to see which parameters influence the communication significantly.

Ključne riječi

Narrowband power line communications; overhead lines; power line channel; real radial power distribution network

Hrčak ID:

272470

URI

https://hrcak.srce.hr/272470

Datum izdavanja:

15.4.2022.

Posjeta: 1.326 *