Sažetak

In accordance with the Regulations of the Rulebook on technical standards related to base support constructions (SL 1986) and the Rulebook on technical standards concerning the maintenance of antenna posts (SL 1984), the aberration of the peak of a post from its vertical position in relation to the footing must not be higher than 1/1000. The inspection of the discrepancies is done by land surveying experts, during the mounting of the posts as well as during regular annual check-ups. This article provides not only the way in which field measurements and calculation procedures are conducted, but also the observations on periodic changes in the discrepancies.

Ključne riječi

base support of an antenna system; verticality; land subsidence; discrepancy; resultant; influence of the sun