hrcak mascot   Srce   HID

Metalurgija, Vol. 55 No. 3, 2016.

Izvorni znanstveni članak

Experimental and numerical analysis of a knee endoprosthesis numerical model

L. Zach ; Czech Technical University in Prague, Faculty of Mechanical Engineering, Prague, Czech Republic
L. Kunčická ; VŠB-Technical University of Ostrava, Faculty of Metallurgy and Materials Engineering, Ostrava-Poruba, Czech Republic
P. Růžička ; Czech Technical University in Prague, Faculty of Mechanical Engineering, Prague, Czech Republic
B. Baghirova ; VŠB-Technical University of Ostrava, Faculty of Metallurgy and Materials Engineering, Ostrava-Poruba, Czech Republic

Puni tekst: engleski, pdf (183 KB) str. 349-352 preuzimanja: 191* citiraj
APA 6th Edition
Zach, L., Kunčická, L., Růžička, P. i Baghirova, B. (2016). Experimental and numerical analysis of a knee endoprosthesis numerical model. Metalurgija, 55 (3), 349-352. Preuzeto s https://hrcak.srce.hr/153617
MLA 8th Edition
Zach, L., et al. "Experimental and numerical analysis of a knee endoprosthesis numerical model." Metalurgija, vol. 55, br. 3, 2016, str. 349-352. https://hrcak.srce.hr/153617. Citirano 16.02.2019.
Chicago 17th Edition
Zach, L., L. Kunčická, P. Růžička i B. Baghirova. "Experimental and numerical analysis of a knee endoprosthesis numerical model." Metalurgija 55, br. 3 (2016): 349-352. https://hrcak.srce.hr/153617
Harvard
Zach, L., et al. (2016). 'Experimental and numerical analysis of a knee endoprosthesis numerical model', Metalurgija, 55(3), str. 349-352. Preuzeto s: https://hrcak.srce.hr/153617 (Datum pristupa: 16.02.2019.)
Vancouver
Zach L, Kunčická L, Růžička P, Baghirova B. Experimental and numerical analysis of a knee endoprosthesis numerical model. Metalurgija [Internet]. 2016 [pristupljeno 16.02.2019.];55(3):349-352. Dostupno na: https://hrcak.srce.hr/153617
IEEE
L. Zach, L. Kunčická, P. Růžička i B. Baghirova, "Experimental and numerical analysis of a knee endoprosthesis numerical model", Metalurgija, vol.55, br. 3, str. 349-352, 2016. [Online]. Dostupno na: https://hrcak.srce.hr/153617. [Citirano: 16.02.2019.]

Sažetak
The aim of this study is to create and verify a numerical model for a Medin Modular orthopedic knee-joint implant by investigating contact pressure, its distribution and contact surfaces. An experiment using Fuji Prescale pressure sensitive films and a finite element analysis (FEA) using Abaqus software were carried out. The experimental data were evaluated using a special designed program and were compared with the results of the analysis. The designed evaluation program had been constructed on the basis of results obtained from a supplementary calibration experiment. The applicability of the numerical model for the real endoprosthesis behavior prediction was proven on the basis of their good correlation.

Ključne riječi
endoprosthesis; knee joint; numerical; analysis; FEM