hrcak mascot   Srce   HID

Stručni rad

The Implantation of Single-Piece Intraocular Lens with Blue-Light Filter

Robert Stanić
Igor Žuljan
Kajo Bućan
Milan Ivanišević
Željko Kovačić

Puni tekst: engleski, pdf (478 KB) str. 301-304 preuzimanja: 490* citiraj
APA 6th Edition
Stanić, R., Žuljan, I., Bućan, K., Ivanišević, M. i Kovačić, Ž. (2007). The Implantation of Single-Piece Intraocular Lens with Blue-Light Filter. Acta clinica Croatica, 46 (4), 301-304. Preuzeto s https://hrcak.srce.hr/21181
MLA 8th Edition
Stanić, Robert, et al. "The Implantation of Single-Piece Intraocular Lens with Blue-Light Filter." Acta clinica Croatica, vol. 46, br. 4, 2007, str. 301-304. https://hrcak.srce.hr/21181. Citirano 25.01.2021.
Chicago 17th Edition
Stanić, Robert, Igor Žuljan, Kajo Bućan, Milan Ivanišević i Željko Kovačić. "The Implantation of Single-Piece Intraocular Lens with Blue-Light Filter." Acta clinica Croatica 46, br. 4 (2007): 301-304. https://hrcak.srce.hr/21181
Harvard
Stanić, R., et al. (2007). 'The Implantation of Single-Piece Intraocular Lens with Blue-Light Filter', Acta clinica Croatica, 46(4), str. 301-304. Preuzeto s: https://hrcak.srce.hr/21181 (Datum pristupa: 25.01.2021.)
Vancouver
Stanić R, Žuljan I, Bućan K, Ivanišević M, Kovačić Ž. The Implantation of Single-Piece Intraocular Lens with Blue-Light Filter. Acta clinica Croatica [Internet]. 2007 [pristupljeno 25.01.2021.];46(4):301-304. Dostupno na: https://hrcak.srce.hr/21181
IEEE
R. Stanić, I. Žuljan, K. Bućan, M. Ivanišević i Ž. Kovačić, "The Implantation of Single-Piece Intraocular Lens with Blue-Light Filter", Acta clinica Croatica, vol.46, br. 4, str. 301-304, 2007. [Online]. Dostupno na: https://hrcak.srce.hr/21181. [Citirano: 25.01.2021.]
Puni tekst: hrvatski, pdf (478 KB) str. 304-304 preuzimanja: 212* citiraj
APA 6th Edition
Stanić, R., Žuljan, I., Bućan, K., Ivanišević, M. i Kovačić, Ž. (2007). Ugradnja jednodijelne intraokularne leće s filtrom za plavo svjetlo. Acta clinica Croatica, 46 (4), 304-304. Preuzeto s https://hrcak.srce.hr/21181
MLA 8th Edition
Stanić, Robert, et al. "Ugradnja jednodijelne intraokularne leće s filtrom za plavo svjetlo." Acta clinica Croatica, vol. 46, br. 4, 2007, str. 304-304. https://hrcak.srce.hr/21181. Citirano 25.01.2021.
Chicago 17th Edition
Stanić, Robert, Igor Žuljan, Kajo Bućan, Milan Ivanišević i Željko Kovačić. "Ugradnja jednodijelne intraokularne leće s filtrom za plavo svjetlo." Acta clinica Croatica 46, br. 4 (2007): 304-304. https://hrcak.srce.hr/21181
Harvard
Stanić, R., et al. (2007). 'Ugradnja jednodijelne intraokularne leće s filtrom za plavo svjetlo', Acta clinica Croatica, 46(4), str. 304-304. Preuzeto s: https://hrcak.srce.hr/21181 (Datum pristupa: 25.01.2021.)
Vancouver
Stanić R, Žuljan I, Bućan K, Ivanišević M, Kovačić Ž. Ugradnja jednodijelne intraokularne leće s filtrom za plavo svjetlo. Acta clinica Croatica [Internet]. 2007 [pristupljeno 25.01.2021.];46(4):304-304. Dostupno na: https://hrcak.srce.hr/21181
IEEE
R. Stanić, I. Žuljan, K. Bućan, M. Ivanišević i Ž. Kovačić, "Ugradnja jednodijelne intraokularne leće s filtrom za plavo svjetlo", Acta clinica Croatica, vol.46, br. 4, str. 304-304, 2007. [Online]. Dostupno na: https://hrcak.srce.hr/21181. [Citirano: 25.01.2021.]

Sažetak
The aim of the study was to evaluate intraoperative and postoperative performance of the single-piece intraocular lens with blue light filter after cataract phacoemulsification. This prospective study included 18 patients (18 eyes) undergoing operation and implantation of a single-piece AcrySof SN60AT foldable acrylic lens (Alcon, Forth Worth, TX, USA) between December 2005 and February 2006. Intraocular lens (IOL) folding, operative and postoperative complications, easiness of IOL implantation through a 3.2-mm incision, haptic flexibility, IOL centration in the capsular bag, visual acuity, posterior capsular opacification and color test were analyzed. Lens folding was easy in all cases. In three cases, the leading haptic did not pass easy through the incision, but unfolding was also easy. After six months, the best corrected visual acuity was 0.85 (Snellen chart), which correlated with the preexisting posterior segment pathology. Color perception was not affected in patients without ocular pathology. Accordingly, implantation of the single-piece AcrySof Natural IOL was found to be easy. The implantation was the same as in other types of foldable lenses and there was no impairment of color perception or visual acuity.

Ključne riječi
Lenses - intraocular, sight prosthesis fitting; Lens implantation - intraocular; Phacoemulsification; Biocompatible materials