hrcak mascot   Srce   HID

Izvorni znanstveni članak

Applicability of bovine tibia as a model in research on various osteosynthesis techniques

VLADIMIR ŠIŠLJAGIĆ ; Department of Surgery, Faculty of Medicine, J. J. Strossmayer University of Osijek, Osijek, Croatia
SAVO JOVANOVIĆ ; Department of Orthopedics, Clinical Hospital Center Osijek, Osijek, Croatia
TOMISLAV MRČELA ; 3Faculty of Electrical Engineering, J. J. Strossmayer University of Osijek, Osijek, Croatia
VASILIJE NIKOLIĆ ; Department of Anatomy and Neurosciences, Faculty of Medicine, J. J. Strossmayer University of Osijek, Osijek, Croatia
RADIVOJE RADIĆ ; Department of Anatomy and Neurosciences, Faculty of Medicine, J. J. Strossmayer University of Osijek, Osijek, Croatia
VJEKOSLAV WERTHEIMER ; Department of Anatomy and Neurosciences, Faculty of Medicine, J. J. Strossmayer University of Osijek, Osijek, Croatia
TANJA KOVAČ ; Department of Anatomy and Neurosciences, Faculty of Medicine, J. J. Strossmayer University of Osijek, Osijek, Croatia
MILANKA MRČELA ; Department of Pathology, Faculty of Medicine, J. J. Strossmayer University of Osijek, Osijek, Croatia

Puni tekst: engleski, pdf (152 KB) str. 59-62 preuzimanja: 313* citiraj
APA 6th Edition
ŠIŠLJAGIĆ, V., JOVANOVIĆ, S., MRČELA, T., NIKOLIĆ, V., RADIĆ, R., WERTHEIMER, V., ... MRČELA, M. (2010). Applicability of bovine tibia as a model in research on various osteosynthesis techniques. Periodicum biologorum, 112 (1), 59-62. Preuzeto s https://hrcak.srce.hr/52696
MLA 8th Edition
ŠIŠLJAGIĆ, VLADIMIR, et al. "Applicability of bovine tibia as a model in research on various osteosynthesis techniques." Periodicum biologorum, vol. 112, br. 1, 2010, str. 59-62. https://hrcak.srce.hr/52696. Citirano 15.11.2019.
Chicago 17th Edition
ŠIŠLJAGIĆ, VLADIMIR, SAVO JOVANOVIĆ, TOMISLAV MRČELA, VASILIJE NIKOLIĆ, RADIVOJE RADIĆ, VJEKOSLAV WERTHEIMER, TANJA KOVAČ i MILANKA MRČELA. "Applicability of bovine tibia as a model in research on various osteosynthesis techniques." Periodicum biologorum 112, br. 1 (2010): 59-62. https://hrcak.srce.hr/52696
Harvard
ŠIŠLJAGIĆ, V., et al. (2010). 'Applicability of bovine tibia as a model in research on various osteosynthesis techniques', Periodicum biologorum, 112(1), str. 59-62. Preuzeto s: https://hrcak.srce.hr/52696 (Datum pristupa: 15.11.2019.)
Vancouver
ŠIŠLJAGIĆ V, JOVANOVIĆ S, MRČELA T, NIKOLIĆ V, RADIĆ R, WERTHEIMER V i sur. Applicability of bovine tibia as a model in research on various osteosynthesis techniques. Periodicum biologorum [Internet]. 2010 [pristupljeno 15.11.2019.];112(1):59-62. Dostupno na: https://hrcak.srce.hr/52696
IEEE
V. ŠIŠLJAGIĆ, et al., "Applicability of bovine tibia as a model in research on various osteosynthesis techniques", Periodicum biologorum, vol.112, br. 1, str. 59-62, 2010. [Online]. Dostupno na: https://hrcak.srce.hr/52696. [Citirano: 15.11.2019.]

Sažetak
Background and Purpose: The main problem in experimental research
in traumatology and orthopedics is unavailability of a large number of
samples of human origin. In this research, standard and modified osteosyntheses were performed on bovine tibia to determine whether bovine tibia can be used as a model in biomechanical research on two or more methods of osteosynthesis.

Materials and Methods: Investigations were carried out on six preparations of cadaveric human tibia and on six preparations of bovine tibia with the use of device for static and dynamic research on long bone model. The bones were artificially broken and then osteosynthesis was performed on them in two ways: applying the standard method and the modified method with bone cement. The aim of these investigations was to determine the size of the axial force and torsion moment that can be exerted to apply static and dynamic loading on the macerated cadaveric tibia and bovine tibia without breaking the bone or causing its permanent deformation.

Results: Investigations conducted on preparations of bovine tibia and
cadaveric human tibia showed that there was not even minimal deformation of the bovine tibia in both standard and modified osteosynthesis. There was no shift in torsion angle at all with all three values of torsion moment applied in these investigations. This result was obtained in both standard and modified osteosynthesis. The results showed that in both bovine and human preparations the loosening occurred sooner when standard osteosynthesis
was applied.

Conclusion: In conclusion, the bovine bone has good potential for use as material for biomechanical experiments.

Ključne riječi
bovine bone; human cadaver bone; osteosynthesis; biomechanics

Hrčak ID: 52696

URI
https://hrcak.srce.hr/52696

Posjeta: 586 *