Skoči na glavni sadržaj

Prethodno priopćenje

https://doi.org/10.15255/KUI.2017.017

Immobilization of Tyrosinase on (3-Aminopropyl)triethoxysilane-Functionalized Carbon Felt-Based Flow-Through Detectors for Electrochemical Detection of Phenolic Compounds

Zheng Zhou ; School of Chemical Engineering, University of Science and Technology Liaoning, 185 Qianshan Road, Hi-tech zone, Anshan, Liaoning, 114 501, P.R. China
Yue Wang ; School of Chemical Engineering, University of Science and Technology Liaoning, 185 Qianshan Road, Hi-tech zone, Anshan, Liaoning, 114 501, P.R. China
Zhiqiang Zhang ; School of Chemical Engineering, University of Science and Technology Liaoning, 185 Qianshan Road, Hi-tech zone, Anshan, Liaoning, 114 501, P.R. China
Yan Zhang ; School of Chemical Engineering, University of Science and Technology Liaoning, 185 Qianshan Road, Hi-tech zone, Anshan, Liaoning, 114 501, P.R. China
Yasushi Hasebe ; Department of Life Science and Green Chemistry, Saitama Institute of Technology, 1690 Fusaiji, Fukaya, Saitama, 369-0293, Japan
Yuming Song ; School of Chemical Engineering, University of Science and Technology Liaoning, 185 Qianshan Road, Hi-tech zone, Anshan, Liaoning, 114 501, P.R. China
Cuiping Wang ; School of Chemical Engineering, University of Science and Technology Liaoning, 185 Qianshan Road, Hi-tech zone, Anshan, Liaoning, 114 501, P.R. China


Puni tekst: engleski pdf 686 Kb

str. 373-380

preuzimanja: 583

citiraj


Sažetak

Tyrosinase (TYR) was covalently immobilized onto amino-functionalized carbon felt (CF) surface via glutaraldehyde (GA). Prior to the TYR-immobilization, primary amino group was introduced to the CF surface by treatment with 3-aminopropyltriethoxysilane (APTES). The resulting TYR-immobilized CF was used as a working electrode unit of an electrochemical flow-through detector for mono- and di-phenolic compounds (i.e., catechol, p-cresol, phenol and p-chlorophenol). Additionally, flow injection peaks based on electroreduction of the enzymatically produced o-quinone species were detected at −0.05 V vs. Ag/AgCl. The resulting TYR/GA/APTES/CF biosensor responded well to all compounds tested with limits of detection range from 7.5 to 35 nmol l–1 (based on three times S/N ratio). Moreover, such modified electrode exhibits good stability and reproducibility for catechol. No serious degradation of the peak current was found over 30 consecutive injections.


This work is licensed under a Creative Commons Attribution 4.0 International License.

Ključne riječi

tyrosinase; carbon felt; (3-aminopropyl)triethoxysilane; flow-through detector

Hrčak ID:

185074

URI

https://hrcak.srce.hr/185074

Datum izdavanja:

31.7.2017.

Podaci na drugim jezicima: hrvatski

Posjeta: 1.520 *