Skoči na glavni sadržaj

Prethodno priopćenje

https://doi.org/10.17113/ftb.62.03.24.8492

Effect of Ethyl Acetate on the Defatting of Leaves in the Extraction of Stevia rebaudiana Bertoni

Liliana Celaya orcid id orcid.org/0000-0003-4288-8215 ; Department of Chemical Engineering, National Scientific and Technical Research Council (CONICET UNaM), Félix de Azara 1552, 3300-Posadas, Argentina
Nicolás Kolb Koslobsky orcid id orcid.org/0000-0002-1923-8241 ; Central Laboratory, School of Exact, Chemical and Life Sciences, Misiones National University, Félix de Azara 1552, 3300-Posadas, Argentina


Puni tekst: engleski pdf 714 Kb

str. 354-360

preuzimanja: 28

citiraj

Preuzmi JATS datoteku


Sažetak

Research background. The process for producing purified steviol glycosides from Stevia rebaudiana leaves (stevia) generally involves pretreatments, extraction, purification and crystallization. Pre-extraction or defatting can sometimes be a part of this process. It can remove impurities of low polarity, such as chlorophyll and fatty compounds. Nonpolar solvents can be used to defat stevia leaves.
Experimental approach. In this study, we investigated ethyl acetate as a pre-extraction solvent for the defatting of dried and crushed stevia leaves. We compared pure ethyl acetate and water-saturated ethyl acetate as pre-extraction solvents in percolation extraction. We then evaluated the effects of pre-extraction on the concentration and purity of the extracts obtained with ethanol/water solvents.
Results and conclusions. The recovery of nonpolar solvents was 2.3–3.9 % in pure ethyl acetate and 3.4–4.5 % in water-saturated ethyl acetate (from 40 to 60 °C). A low steviol glycoside loss can occur only with water-saturated ethyl acetate (on dry mass basis <0.5 %). In the Soxhlet extraction, the obtained yields were 8.43 with pure ethyl acetate and 10.44 % with water-saturated ethyl acetate. The steviol glycoside loss in the Soxhlet extraction was 10.70 % with water-saturated ethyl acetate. Defatted and non-defatted leaves were extracted with two ethanol/water solvents. Comparison of the results showed higher concentrations of glycoside in the pretreated leaves.
Novelty and scientific contribution. The pre-extraction with ethyl acetate followed by the extraction with ethanol/water solvent lead to a higher concentration of steviol glycosides and a higher purity of the extracts. Ethyl acetate can be used as a pre-extraction solvent for the defatting of stevia leaves in the industrial production of this sweetener.

Ključne riječi

production of stevioside and rebaudioside A; Stevia rebaudiana leaves; percolation bed; pre-extraction with ethyl acetate

Hrčak ID:

321934

URI

https://hrcak.srce.hr/321934

Datum izdavanja:

31.10.2024.

Podaci na drugim jezicima: hrvatski

Posjeta: 199 *




INTRODUCTION

Stevia rebaudiana (Bert) Bertoni, commonly called stevia, is a rich source of natural sweeteners steviol glycosides. These organic compounds are chemically composed of glycoside groups linked to the diterpene steviol. In 2007, the Joint FAO/WHO Expert Committee on Food Additives approved 10 steviol glycosides as additives (1). Recently, 20 new steviol glycosides have been isolated and characterised (2). Steviol glycosides are used in many countries in food formulations and for different pharmaceutical purposes (3).

The percentage of steviol glycosides in stevia leaves varies between 4 and 20 %. The main steviol glycosides in the leaves are stevioside (1–10 %), rebaudioside A (2–13 %) and rebaudioside C (0.5–1.5 %). Other steviol glycosides are usually present in smaller amounts (4-6). Stevioside (Stv) and rebaudioside A (RbA) are largely responsible for the sweetness of stevia leaves, extracts and commercial products (7,8). RbA, which has an additional glucose unit relative to Stv, is superior in terms of taste quality (9). Rebaudioside C (RbC), with different sugar moiety (rhamnose) compared to RbA, has been shown to act as a flavour enhancer together with RbA. Rebaudioside D (RbD), which has desirable sweetening properties, occurs naturally in stevia plants in low concentrations (10). The physicochemical properties of steviol glycosides differ from each other.

Steviol glycoside production generally involves pretreatment, extraction, purification and crystallization. The first step is a solid-liquid extraction of the pretreated stevia leaves (11,12). The steviol glycosides are extracted from the leaves with water or alcohol (13,14). The product of the extraction step is a coloured and dense mixture containing steviol glycosides along with other components, such as saccharides, proteins, oils, pigments, phenolic compounds, gums, colloids and other impurities (15,16). The obtained extract is usually subjected to a multi-step purification to obtain the individual components, namely Stv, RbA, RbC and mixtures of steviol glycosides (13,17,18).

Pre-extraction or defatting can also be used in this process to remove impurities of low polarity, for example chlorophyll and fatty compounds, by boiling the plant material with the solvent (19-21). Nonpolar solvents such as hexane, petroleum ether or CO2 can be used (22-24). In this context, there are some studies investigating alternatives to carry out this separation step with different procedures and solvents (25,26).

Previously, Formigoni et al. (25) used a column to treat stevia leaves with ethanolic solvent. Ciotta et al. (26) used leaves pretreated with ethanol for the percolation extraction of steviol glycosides with boiling water as solvent. In a previous work, we optimized the temperature and percentage of ethanol to extract Stv and RbA from stevia leaves in a percolation extractor. The optimal extraction conditions that gave the best steviol glycoside extraction kinetics were 70 °C and 35 % ethanol (14). In addition, the optimal extraction conditions that gave maximum purity were 70 % ethanol at 30–70 °C. In the present study, we aim to investigate the effects of using ethyl acetate to defat dried and crushed stevia leaves. We compared pure ethyl acetate and water-saturated ethyl acetate as solvents for pre-extraction, and investigated the effect of pre-extraction on the concentration and purity of stevia extracts obtained with ethanol/water as solvent.

MATERIALS AND METHODS

Chemicals

Ethanol and ethyl acetate were obtained from Cicarelli (Reagents S.A., San Lorenzo, Argentina). The distilled water used for the extraction was deionized in a Milli-Q system (Millipore Sigma, Bedford, MA, USA). HPLC-grade acetic acid, acetonitrile, water and ethanol were obtained from Merck (Darmstadt, Germany). Crystals of stevioside (Stv; 98.5 % purity), rebaudioside A (RbA; 99.5 % purity), rebaudioside B (RbB; 99.5 % purity) and rebaudioside C (RbC; 99.5 % purity) were obtained in-house (Project 16Q1204-IDP) by preparative column chromatography and successive recrystalizations (27). The crystals were compared with steviol glycoside United States Pharmacopeia (USP) reference standard solution (Sigma–Aldrich, Merck, Steinheim, Germany). Other chemicals used were of analytical grade.

Binary solvents were prepared at room temperature. The binary solvent used for defatting of leaves (water-saturated ethyl acetate) was prepared by adding water to ethyl acetate up to saturation of 3.3 % m/m (28). The binary solvents (ethanol/water solvents) used for the extractions were prepared according to Celaya et al. (3).

Raw materials

Stevia (Stevia rebaudiana) was harvested at the experimental farm in Posadas (Departamento Capital, Argentina) when the flowers were opened at 0–5 %. The samples were collected after sun-drying for 3–4 days. The dried leaves were crushed to obtain particles with mesh size of 5–40. The residual moisture content was separated from the leaves by drying the samples at (60±2) °C until they reached a constant mass.

Pre-extractions

Pure ethyl acetate (PEtAc) and water-saturated ethyl acetate (SEtAc) were used to defat stevia leaves. Ground stevia leaves used for the assays were dried at 60 °C until the remaining water was removed.

The solid/liquid pre-extractions were carried out using a laboratory scale percolator according to Celaya et al. (14). The percolation temperature was controlled by a thermostatic system with recirculation of heating water (model CT1150; Schott Geräte, Mainz, Germany). The extraction temperature was measured with three thermometers.

For each experiment, 200 g of pre-dried leaves were packed and impregnated with 1300 mL of solvent. After impregnation (10 min), the solvent was eluted by gravity and 5 fractions of 200 mL were obtained. The total percolation time was 60 min; the mean flow rate was (16.7±1.4) mL/min. After extraction, the 5 fractions were rapidly cooled to room temperature and mixed. Each extraction was carried out in duplicate. Total volume of extracts (1000 mL) was used to compare the results of different working conditions. The extracts were filtered and diluted in m(ethanol)/m(water)=70:30 m/m for analysis.

Extractions with ethanol/water mixtures

The mixed solvent was removed by evaporation at 60 °C. The samples were then vacuum dried to constant mass. Defatted stevia leaves were dried at 60 °C for three days and then they were vacuum dried until the remaining solvent was removed. Untreated stevia leaves were dried at 60 °C after the extractions.

Defatted and untreated stevia leaves were extracted at 70 °C as previously described (14). Two ethanol/water solvents were used: w(ethanol)=35 % (EtOH35) and 70 % (EtOH70). During percolation, the binary solvent was eluted by gravity and 4 fractions of 250 mL were obtained. The total percolation time was 60 min. The total extract volume (1000 mL) was used to compare the results of different operating conditions.

Soxhlet extraction

For comparison, Soxhlet extractions were carried out using PEtAc and SEtAc as defatting solvents. Ground stevia leaves were pre-dried at 60 °C for 2 h and then 20 g were placed in the extraction thimble (14). The thimble was placed in the Soxhlet extractor. The plant material was extracted with 500 mL of solvent for 8.5 h. The remaining solvent was removed by evaporation at 60 °C until constant mass was reached. The extracted materials and extracts were used for analysis. Soxhlet extractions were conducted in duplicate.

Analytical determinations

The obtained extracts were filtered and diluted to w(ethanol)=70 % for analysis. The steviol glycosides in leaves and extracts were quantified with a high-performance liquid chromatography diode array detector (HPLC-DAD) using the external standard method (29). Stock solutions of 0.2–1.0 g/L of the standard compounds (Stv, RbA and RbC) in w(ethanol)=70 % were prepared for the calibration curve. The compounds in each sample were identified by comparing their retention times with those of the standards. Rebaudioside D (RbD) was quantified in the same way as RbA.

Ground stevia leaves contained the following mass fractions on dry mass basis of individual steviol glycosides (in %): RbA (10.3±0.4), Stv (3.0±0.1), RbC (1.1±0.1), RbB (0.4±0.1) and RbD (0.4±0.1). The mass fraction of all steviol glycosides was (15.2±0.4) %. The moisture mass fraction was (5.3±0.5) %.

The extraction process was monitored by measuring the mass fractions of Stv, RbA and RbC in leaves and extracts. The process variables determined were: concentration of glycosides γ/(g/L) and their recovery and purity expressed as mass fraction (w/%) on dry mass basis (14). The total extracted solid (TES) mass fraction was measured after drying 10 mL of extract at 80–102 °C on a tared steel plate until a constant mass (27).

Statistical analyses

Statistical analyses were performed with R Studio, v. 4.0.3 (30). Mean values were compared using a two-way ANOVA and post-hoc Tukey’s tests to determine differences with statistical significance. Differences were considered significant at p<0.05.

RESULTS AND DISCUSSION

Effect of defatting with ethyl acetate

Research into the defatting step would be of interest for the industrial stevia process. To investigate the potential of defatting process with ethyl acetate, two nonpolar solvents, PEtAc and SEtAc, were tested.Fig. 1 shows the recovery of nonpolar compounds with PEtAc and SEtAc at different temperatures (40, 50 and 60 °C). The defatting of stevia leaves shows a dependence on solvent (Fig. 1a) and temperature (Fig. 1b). There was no interaction between solvent and temperature (p=0.19049). The recovery of steviol glycosides on dry mass basis in the pre-extraction with PEtAc varied from 2.3 to 3.9 % (from 40 to 60 °C), while with SEtAc, it varied from 3.4 to 4.5 %.

Fig. 1 Dependence of stevia leaf defatting yield on dry mass basis on: a) defatting solvent (p=0.00381) and b) temperature (p<0.00000) and c) steviol glycoside loss, in the pre-extraction with SEtAc (p=0.0423). x and y mark mean values that are significantly different (p<0.05). PEtAc=pure ethyl acetate, SEtAc=water-saturated ethyl acetate
FTB-62-354-f1

Various pretreatment strategies have been used in the stevia industry to increase the efficiency of the extraction (15). Pretreatments of leaves may be appropriate depending on their lipid content (22-24). Nonpolar solvents such as hexane or petroleum ether can be used. In our study, we investigated ethyl acetate as a pre-extraction solvent for the defatting of dried and crushed stevia leaves. To the best of our knowledge, there are no reports on the use of ethyl acetate in the pre-extraction of steviol glycosides from stevia leaves. Our results show that ethyl acetate and water-saturated ethyl acetate have great potential for industrial use as a pre-extraction solvent for defatting stevia leaves.

Multiple extractions were carried out in a Soxhlet apparatus with PEtAc and SEtAc as defatting solvents. The obtained yields on dry mass basis were (8.4±1.6) and (10.4±0.9) of total solids, with PEtAc and SEtAc, respectively. These analytical results show a great potential of the nonpolar solvent for the extraction of compounds other than steviol glycosides from stevia leaves.

Previous work has investigated the performance of different solvents in the defatting of stevia leaves. According to these results, oil recovery in petroleum ether extraction was 3.7–4.3 % of the leaves (22,31). In cold extraction with petroleum ether (tb=40–60 °C), the oil recovery was 3.15–5.45 % (19), and in Soxhlet extraction 2.00–6.00 %. In the present study, the best condition for defatting the leaves was 60 °C when using SEtAc (Fig. 1).

The polarity indices of the solvents can partly explain the observed behavior. The normalized polarity indices ET range from 0.000 for the least polar solvent (tetramethylsilane) to 1.000 for the most polar solvent (water). The normalized ET values are <0.125 for petroleum ether, 0.009 for hexane and 0.228 for ethyl acetate (32,33). The low polarity of ethyl acetate could be partly responsible for the nonpolar recovery in the purification of stevia leaves.

In some purification processes, ethyl acetate can be used industrially as a replacement for petroleum ether (32). To achieve complete leaching of the plant material, additional solvents need to be added to the percolator bed (14). Additional volumes of solvent are required in pre-extractions with the nonpolar solvent.

The loss of steviol glycosides during pre-extraction

During the pretreatment of leaves, several substances can be extracted together with nonpolar impurities. These co-extracted compounds may be steviol glycosides. The loss of steviol glycosides during pre-extraction was monitored in the defatting experiments. The loss of steviol glycosides was not observed during the pre-extractions with PEtAc. The graphical results of steviol glycoside loss in the pre-extractions with SEtAc are shown inFig. 1c. Water-saturated ethyl acetate SEtAc resulted in a loss of 3.9–4.6 % of steviol glycosides (from 40 to 60 °C).

Previously, Formigoni et al. (25) used ethanolic solvent for the pretreatment of stevia leaves and found a decrease in fatty acid content (68 %) and a loss of sweeteners of 9.5 % (mainly RbA). In the present study, the loss of steviol glycosides at 60 °C with SEtAc was 4.6 % (mainly RbA and Stv).

The multiple extractions carried out with PEtAc yielded 8.4 % with a loss of steviol glycosides of less than 1.0 %. In the Soxhlet extraction with PEtAc, mainly Stv and RbA with nonpolar impurities were extracted. Multiple extractions with SEtAc yielded 10.44 % with a loss of steviol glycosides of (10.7±6.2) %. An important feature of the use of SEtAc in Soxhlet extraction is that the greatest loss occurs in Stv (40.8±5.2) compared to RbA (3.9±2.9) and RbC (16.1±5.4). The resulting defatted leaves have a mean ratio of w(RbA)/w(Stv)=4.9.

Extraction with ethanol/water solvents

Defatted and non-defatted leaves were extracted with two ethanol/water solvents: EtOH35 and EtOH70.Table 1 shows the concentrations of steviol glycosides in the raw materials used for the ethanol/water extractions.Table 2 shows the results of the extractions with binary solvents. These preliminary results show that the concentrations of steviol glycosides are higher in the pretreated leaves.

Table 1 Mass fraction on dry mass basis of main steviol glycosides present in the raw materials used for the ethanol/water extractions
w(steviol glycoside)/%
Raw materialStvRbARbC
Untreated(2.90±0.07)a(10.22±0.06)a(1.05±0.02)a
PEtAc(3.34±0.01)b(11.05±0.04)b(1.11±0.03)a
SEtAc(3.30±0.01)b(10.66±0.12)ab(1.02±0.02)a

The values with different letters in superscript in the same column are significantly different (p<0.05). Stv=stevioside, RbA=rebaudioside A, RbC=rebaudioside C, PEtAc=pure ethyl acetate and SEtAc=water-saturated ethyl acetate

Table 2 Concentration of steviol glycosides and TES during extraction of untreated and pretreated stevia leaves
γ/(g/L)
Pre-extractionSolventStvRbARbCTSGTES
UntreatedEtOH35(3.9±0.2)a(15.610.4)a(1.9±0.1)ab(21.84±0.02)a(90.7±0.7)a
EtOH70(3.8±0.2)a(15.98±0.03)a(1.43±0.01)a(21.2±0.2)a(70.1±1.5)b
PEtAcEtOH35(6.13)b(19.80)b(2.14)b(29.27)b(89.71)a
EtOH70(5.35)b(17.49)b(1.82)a(25.73)b(77.62)b
SEtAcEtOH35(6.10)b(20.68)b(2.13)b(30.07)b(86.88)a
EtOH70(5.56)b(19.03)b(1.88)ab(27.70)b(76.87)b
p*pre-extraction0.0009210.011500.014210.00411>0.05
solvent>0.05>0.050.00466>0.050.0032
pre-extraction × solvent>0.05>0.05>0.05>0.05>0.05

*Statistical significance for linear models in R Studio (30). The results were obtained in a laboratory scale percolator. Mean values with different letters in superscript in the same column are significantly different (p<0.05). EtOH35=w(ethanol)=35 %, EtOH70=w(ethanol)=70 %, Stv=stevioside, RbA=rebaudioside A, RbC=rebaudioside C, TSG=total steviol glycosides, TES=total extracted solids, PEtAc=pure ethyl acetate and SEtAc=water-saturated ethyl acetate

The effect of the extraction solvents on the purity is shown inTable 3. The comparison of the results shows that a pre-extraction with ethyl acetate followed by an extraction with ethanol/water leads to a higher purity of the extracts. According to our earlier studies, EtOH70 (at 70 °C) is the optimum extraction condition that gives maximum purity (14).

Table 3 Purity of ethanol/water extracts
w/%
Pre-extractionSolventStvRbARbCTSGw(RbA)/w(Stv)
UntreatedEtOH35(4.1±0.2)a(17.2±0.6)a(2.1±0.2)a(23.48±0.02)a(4.05±0.09)a
EtOH70(4.1±0.2)a(22.8±0.5)ab(2.05±0.02)a(30.3±0.9)ab(4.2±0.2)a
PEtAcEtOH35(6.83)b(22.07)ab(2.39)b(32.63ab(3.23)b
EtOH70(6.89)b(22.53)ab(2.34)b(33.15)ab(3.27)b
SEtAcEtOH35(7.02)b(23.80)ab(2.45)b(34.61)ab(3.39)b
EtOH70(7.23)b(24.76)b(2.45)b(36.03)b(3.42)b
p*pre-extraction0.0009210.002290.009370.002270.0011
solvent>0.050.00156>0.050.00297>0.05
pre-extraction×solvent>0.050.0512>0.050.0937>0.05

*Statistical significance for linear models in R Studio (30). For TSG and RbA the model used includes the interaction of pre-extraction and solvent. Mean values with different letters in superscript in the same column are significantly different (p<0.05). EtOH35=w(ethanol)=35 %, EtOH70=w(ethanol)=70 %, Stv=stevioside, RbA=rebaudioside A, RbC=rebaudioside C, TSG=total steviol glycosides, PEtAc=pure ethyl acetate and SEtAc=water-saturated ethyl acetate

When comparing the purity results of percolation with ethanol/water solvents, we found that SEtAc is the best solvent for obtaining an extract with the best purity (Table 3). The results show purity values of 34.6 and 36.0 % with EtOH35 and EtOH70, respectively.

In addition to the steviol glycoside loss in the pre-extraction with SEtAc, a lower w(RbA)/w(Stv) ratio was measured with ethyl acetate than with untreated leaves (Table 3). Without pre-extraction, several low-polarity impurities can be co-extracted in the extraction process. Pre-extraction promotes a higher process yield and better purity. However, co-extracted substances, including steviol glycosides, can also be extracted together with nonpolar impurities. In addition, the extraction of steviol glycosides with polar solvents requires subsequent removal of solvent residues (20).

Effect of pre-extraction on the efficiency of extraction with ethanol/water solvents

The efficiency of the extraction of steviol glycosides and total extracted solids (TES) with EtOH35 and EtOH70 was monitored in the percolation extractions. Percolation concentrations of steviol glycosides and TES ​​were measured.Fig. 2 shows the percolation data plotted for untreated leaves (Fig. 2a), leaves pretreated with PEtAc (Fig. 2b) and leaves pretreated with SEtAc (Fig. 2c). According to the obtained results, EtOH35 is superior to EtOH70, as it allows a faster recovery of steviol glycosides (14). In the percolation process, a large part of the TES appeared immediately in the pretreated leaves (Fig. 2b andFig. 2c). Strikingly, the use of SEtAc significantly increased the recovery of steviol glycosides in the percolation extraction. This result adds to the higher purity achieved when using EtAc.

Fig. 2 Extraction yield (Y) of steviol glycosides and total extracted s with different solvents w(ethanol)=35 % (EtOH35) and 70 % (EtOH70) (percolation values): a) untreated leaves, b) leaves pretreated with PEtAc, and c) leaves pretreated with SEtAc. TSG=total steviol glycosides, TES=total extracted solids, PEtAc=pure ethyl acetate and SEtAc=water-saturated ethyl acetate
FTB-62-354-f2

Finally, a critical consideration must be made to define the application of a defatting operation in the process. This operation requires an additional step in the extraction process, which can increase costs and time, and require the use of complex equipment (15). For an environmentally friendly process, the possible use of ethyl acetate extracts as a source of chlorophyll and fatty compounds can be considered in future studies, as well as the possible recycling of ethyl acetate in the stevia process. A solvent recycling process can be used for the recovery and subsequent reuse of ethyl acetate, which is environmentally friendly from an ecological point of view.

CONCLUSIONS

Defatting can be suitable for the pretreatment of stevia leaves in industrial processes. In this study, we report about the use of ethyl acetate for the defatting of stevia leaves in a percolator extractor. We investigated pure ethyl acetate (PEtAc) and water-saturated ethyl acetate (SEtAc) and the results show that ethyl acetate is appropriate for the removal of nonpolar impurities from stevia leaves. Pre-extraction with ethyl acetate promotes a higher extraction yield of steviol glycosides and their highest purity. SEtAc removes impurities from stevia leaves more efficiently, but it may cause a loss of steviol glycosides.

Ethyl acetate can be used as a pre-extraction solvent for defatting stevia leaves. Moreover, the solvent recycling operation can make the process economic and environmentally friendly. In this regard further investigation of the pre-extraction with ethyl acetate and its effect on stevia purification should be carried out in the future.

ACKNOWLEDGEMENTS

The authors are grateful to Cristina E. Mayol for her critical English revision and thanks to Dario J. Ferreyra for his support and collaboration.

Notes

[1] Financial disclosure FUNDING

The financial support was received from Project UNaM FCEQyN-16Q624 (to N. Kolb Koslobsky) and Project UNaM FCEQyN-16Q1204-IDP (to L. Celaya). For this study, L. Celaya was supported by post doc grant from CONICET (National Council for Scientific and Technological Research).

[2] Conflicts of interest CONFLICT OF INTEREST

The authors declare that they have no known competing financial interests or personal relationships that could have influenced the work reported in this article.

REFERENCES

1 

69th JECFA – Chemical and Technical Assessment (CTA). Steviol glycosides, chemical and technical assessment (CTA, 2007) revised by H. Wallin for the 69th JECFA 2008. Original by H. Wallin for the 63rd JECFA, Revised by Paul M. Kuznesof for the 68th JECFA. Rome, Italy: Food and Agriculture Organization of the United Nations (FAO); 2008. Available from:https://openknowledge.fao.org/server/api/core/bitstreams/0336fea3-bec2-4c6d-b5e9-0e201c9b6872/content.

2 

Wölwer-Rieck U. The leaves of Stevia rebaudiana (Bertoni), their constituents and the analyses thereof: A review. J Agric Food Chem. 2012;60(4):886–95. https://doi.org/10.1021/jf2044907 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/22250765

3 

Celaya L, Kolb E, Kolb N. Solubility of stevioside and rebaudioside A in water, ethanol and their binary mixtures. Int J Food Stud. 2016;5(2):158–66. https://doi.org/10.7455/ijfs/5.2.2016.a4

4 

Morita T, Morita K, Komai K. High, Rebaudioside-A plant. US patent US 20117884265B2. 2011.

5 

Wang Q. High rebaudioside A plant and methods of producing the same and uses thereof. WIPO patent WO 20120886112 A1. 2012.

6 

Pfister WR, Sehgal S. Natural low caloric sweetener compositions for use in beverages, foods and pharmaceuticals, and their methods of manufacture. US patent US 20110021111A1. 2011.

7 

Geuns JM. Molecules of interest, stevioside. Phytochemistry. 2003;64(5):913–21. https://doi.org/10.1016/S0031-9422(03)00426-6 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/14561506

8 

Kinghorn AD, Wu CD. Soejarto DD. Stevioside. Alternative sweeteners. New York, NY, USA: Marcel Dekker Inc; 2001. pp.167-184. https://doi.org/10.1079/BJN2001494 https://doi.org/10.1079/BJN2001494

9 

Dewis ML, Kraut KJ, Merritt D, Salemme RF. Methods for using rebaudioside C as a flavor enhancer. US patent US 20138524785. 2013.

10 

Brower RJ, Carlson TL, Dang B, Gonzalez M, Kennedy MM, Knutson NE. Stevia plants with an increased rebaudioside D content. US patent US 20210068360A1. 2021.

11 

Abelyan VH, Ghochikyan VT, Markosyan AA, Adamyan MO, Abelyan LA. Extraction, separation and modification of sweet glycosides from the Stevia rebaudiana plant. US patent US 20067838044. 2006.

12 

Jonnala KK, Babu GDK, Vijay KK, Paramvir SA. Process for production of steviosides from Stevia rebaudiana Bertoni. US patent US 20060142555. 2006.

13 

Kienle U. Method of making a natural sweetener based on Stevia rebaudiana, and use thereof. US patent US 19925112610. 1992.

14 

Celaya L, Ferrreyra D, Kolb E, Kolb-Koslobsky N. Extraction of stevioside and rebaudioside a from Stevia rebaudiana by percolation with ethanol-water solvents. Argent J Sci Technol. 2022;38:55–62. https://doi.org/10.36995/j.recyt.2022.38.007

15 

Chabot S, Beaulieu M. Extraction method for providing an organic certifiable Stevia rebaudiana extract. US patent US 20130108718. 2013.

16 

Pasquel A, Meireles MAA, Marques MOM, Petenate AJ. Extraction of stevia glicosides with CO2 + water, CO2 + ethanol and CO2 + water + ethanol. Braz J Chem Eng. 2000;17(3):271–82. https://doi.org/10.1590/S0104-66322000000300003

17 

Payzant JD, Laidler JK, Ippolito RM. Method of extracting selected sweet glycosides from the Stevia rebaudiana plant. US patent US 19995962678. 1999.

18 

Wang J, Zhao H, Wang Y, Lau H, Zhou W, Chen C, et al. A review of stevia as a potential healthcare product: Up-to-date functional characteristics, administrative standards and engineering techniques. Trends Food Sci Technol. 2020;203:264–81. https://doi.org/10.1016/j.tifs.2020.07.023

19 

Bitasta M, Swati M. Comparative standardization and physicochemical evaluation of the leaves of Stevia rebaudiana Bertoni from different geographical sources. Pharmacogn J. 2013;3(25):21–6. https://doi.org/10.5530/pj.2011.25.4

20 

Persinos GJ. Method of producing Stevioside. US patent US 19733723410. 1973.

21 

Yoda SK, Marques MOM, Petenate AJ, Meireles MAA. Supercritical fluid extraction from Stevia rebaudiana Bertoni using CO2 and CO2+water: Extraction kinetics and identification of extracted components. J Food Eng. 2003;57:125–34. https://doi.org/10.1016/S0260-8774(02)00281-9

22 

Abou-Arab EA, Abou-Arab AA, Abu-Salem MF. Physico-chemical assessment of natural sweeteners steviosides produced from Stevia rebaudiana Bertoni plant. Afr J Food Sci. 2010;4:269–81. https://doi.org/10.12691/jfnr-2-5-1

23 

Kaushik R, Pradeep N, Vamshi V, Geetha M, Usha A. Nutrient composition of cultivated stevia leaves and the influence of polyphenols and plant pigments on sensory and antioxidant properties of leaf extracts. J Food Sci Technol. 2010;47:27–33. https://doi.org/10.1007/s13197-010-0011-7 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/23572597

24 

Savita SM, Sheela K, Sunanda S, Shankar AG, Ramakrishna P. Stevia rebaudiana - A functional component for food industry. J Hum Ecol. 2004;15(4):261–4. https://doi.org/10.1080/09709274.2004.11905703

25 

Formigoni M, Milani PG, da Silva Avíncola A, Dos-Santos VJ, Benossi L, Dacome AS, et al. Pretreatment with ethanol as an alternative to improve steviol glycosides extraction and purification from a new variety of stevia. Food Chem. 2018;241:452–9. https://doi.org/10.1016/j.foodchem.2017.09.022 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/28958553

26 

Ciotta SR, Zorzenon MRT, Dacome AS, Hodas F, de Almeida do Couto JMF, Fernandes PGM, et al. Extraction of sweeteners from Stevia rebaudiana by semicontinuous percolation of untreated leaves and leaves pretreated with ethanol. J Food Process Preserv. 2022;46(3):e16303. https://doi.org/10.1111/jfpp.16303

27 

Celaya L, Martina P, Kolb-Koslobsky N. Infusions prepared with Stevia rebaudiana: Application of a simplex centroid mixture design for the study of natural sweeteners and phenolic compounds. J Food Sci Technol. 2022;59:55–64. https://doi.org/10.1007/s13197-021-04979-9 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/35068551

28 

Smallwood IM, editor. Handbook of organic solvent properties. Oxford, UK: Butterworth-Heinemann; 1996. https://doi.org/10.1016/B978-0-08-052378-1.50001-3 https://doi.org/10.1016/B978-0-08-052378-1.50001-3

29 

Kolb N, Herrera JL, Ferreyra DJ, Uliana RF. Analysis of sweet diterpene glycosides from Stevia rebaudiana: Improved HPLC method. J Agric Food Chem. 2001;49(10):4538–41. https://doi.org/10.1021/jf010475p PubMed: http://www.ncbi.nlm.nih.gov/pubmed/11599985

30 

R Core Team. RStudio: Integrated development for R, RStudio, R foundation for Statistical Computing, Vienna, Austria; 2024. Available from:https://www.R-project.org/.

31 

Tadhani M, Subhash R. Preliminary studies on Stevia rebaudiana leaves: Proximal composition, mineral analysis and phytochemical screening. J Med Sci. 2006;6(3):321–6. https://doi.org/10.3923/jms.2006.321.326

32 

Kerton F, Marriott R. Introduction. Clark JH, Kraus GA, editors. Alternative solvents for green chemistry. London, UK: The Royal Society of Chemistry;2009;1-30. https://doi.org/10.1039/9781849736824-00001 https://doi.org/10.1039/9781849736824-00001

33 

Reichardt C, Welton T. Solvents and solvent effects in organic chemistry. Weinheim, Germany: Wiley-VCH; 2010. https://doi.org/10.1002/9783527632220 https://doi.org/10.1002/9783527632220


This display is generated from NISO JATS XML with jats-html.xsl. The XSLT engine is libxslt.