Skip to the main content

Original scientific paper

https://doi.org/10.5599/admet.3182

High-sensitivity electrochemical immunosensor for anti-SARS-CoV-2 IgG detection using screen-printed carbon/cerium oxide-gold electrode

Melania Janisha Devi orcid id orcid.org/0000-0002-7165-033X ; Department of Chemistry, Faculty of Mathematics and Natural Sciences, Padjadjaran University, Jl. Raya Bandung-Sumedang Km 21, Jatinangor, Sumedang, West Java 45363, Indonesia
Ratu Shifa Syafira ; Department of Chemistry, Faculty of Mathematics and Natural Sciences, Padjadjaran University, Jl. Raya Bandung-Sumedang Km 21, Jatinangor, Sumedang, West Java 45363, Indonesia
Shabarni Gaffar ; Department of Chemistry, Faculty of Mathematics and Natural Sciences, Padjadjaran University, Jl. Raya Bandung-Sumedang Km 21, Jatinangor, Sumedang, West Java 45363, Indonesia
Irkham Irkham ; Department of Chemistry, Faculty of Mathematics and Natural Sciences, Padjadjaran University, Jl. Raya Bandung-Sumedang Km 21, Jatinangor, Sumedang, West Java 45363, Indonesia
Yasuaki Einaga ; Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama, 223-8522, Japan
Yeni Wahyuni Hartati ; Department of Chemistry, Faculty of Mathematics and Natural Sciences, Padjadjaran University, Jl. Raya Bandung-Sumedang Km 21, Jatinangor, Sumedang, West Java 45363, Indonesia *

* Corresponding author.


Full text: english pdf 1.848 Kb

versions

downloads: 104

cite


Abstract

Background and purpose: Serological assays are essential for evaluating immune responses, including donor screening, vaccine efficacy, and antibody persistence. However, conventional methods are time-consuming and require centralized laboratories. This study aimed to develop a sensitive and rapid electrochemical immunosensor based on a cerium oxide-gold nanocomposite (CeO₂-Au) modified screen-printed carbon electrode (SPCE) for the detection of anti-SARS-CoV-2 IgG, while elucidating the underlying electrochemical sensing mechanism. Experimental approach: CeO₂-Au nanocomposites were synthesized and characterized using UV-Vis, SEM, TEM-EDX, and FTIR. The immuno­sensor was fabricated by immobilizing SARS-CoV-2 Spike receptor-binding domain (RBD) onto the modified SPCE. Electrochemical responses were evaluated using differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) with K₃[Fe(CN)₆] as a redox probe. Key results: The CeO₂-Au nanocomposite enhanced electron transfer and provided a high surface area for biomolecule immobilization. The sensing mechanism is governed by modulation of interfacial electron transfer: binding of IgG to immobilized RBD forms an insulating immunocomplex layer, increasing charge transfer resistance and suppressing faradaic current. The sensor exhibited a wide linear range of 0.01 to 103 ng mL-1, a low detection limit of 2.475 pg mL-1, good stability, and reliable 97.3 to 108.56 % recovery in serum samples. Conclusion: This immunosensor proposed as a sensitive and reliable platform for IgG detection. The study advances understanding of signal transduction mechanisms in nanocomposite-based immunosensors and highlights their potential for rapid serological diagnostics. However, broader clinical validation and selectivity against complex interferents remain necessary.

Keywords

Electrochemical immunoassay; ceria-gold nanohybrid; modified carbon electrode; SARS-CoV-2 IgG antibodies

Hrčak ID:

346785

URI

https://hrcak.srce.hr/346785

Publication date:

14.4.2026.

Visits: 212 *