Electrochemical characterization and detection of vitamin E in real samples

Dominik Goman orcid id orcid.org/0000-0003-0113-0141 ; Josip Juraj Strossmayer University of Osijek, Department of Chemistry *
Valentina Danković ; Josip Juraj Strossmayer University of Osijek, Department of Chemistry
Olivera Galović ; Josip Juraj Strossmayer University of Osijek, Department of Chemistry
Martina Medvidović-Kosanović orcid id orcid.org/0000-0002-9887-9169 ; Josip Juraj Strossmayer University of Osijek, Department of Chemistry

* Corresponding author.


Full text: english pdf 1.191 Kb

page 1-9

downloads: 136

cite

Download JATS file


Abstract

Vitamin E is an important antioxidant and plays an essential role in cellular respiration. At room temperature, it exists in the form of viscous oil and is highly soluble in fat. Vitamin E is a group of eight compounds: four tocopherols and four tocotrienols. In this study, α-tocopherol (α -TOH) was characterized using cyclic and differential pulse voltammetry and was detected with high-performance liquid chromatography in real samples (kale, parsley, and a powdered dietary supplement). Cyclic and differential pulse voltammograms have shown one oxidation peak which corresponds to the oxidation of α -TOH. In the oxidation of α -TOH, rapid two-electron oxidation coupled with one proton loss \((-2e^{-}/-1H^{+})\) occurred, and a diamagnetic cation \((\alpha -TO^{+}) \) was formed. Oxidation of α -TOH α is an irreversible and a diffusion-controlled process since the linear correlation between anodic peak current, Ip,a, and the square root of scan rate \((v)^{1/2}\) was observed. It was also determined that the anodic peak current of α -TOH increases with the increase of its concentration (linear response was obtained in the concentration range from 0.43 \(mg/dm^{3} \) to 70.41 \(mg/dm^{3} \)). The obtained values of α -TOH in real samples were 8.267 mg/kg for parsley, 1.492 mg/kg for kale, and 0.067 mg/kg for powdered dietary supplement.

Keywords

α –tocopherol; cyclic voltammetry; differential pulse voltammetry; high-performance liquid chromatography; vitamin E

Hrčak ID:

318160

URI

https://hrcak.srce.hr/318160

Publication date:

20.6.2024.

Visits: 385 *




1. Introduction

Vitamins are essential micronutrients required for the normal functioning of living organisms. There are water-soluble and fat-soluble vitamins. Vitamin E belongs to the group of fat-soluble vitamins. It consists of eight compounds: four tocopherols and four tocotrienols. Each of these groups possesses four isoforms α, β, γ and δ based on the location of a specific methyl group on chromanol at positions 5, 7 and 8 (Schneider, 2005).

The most biologically active form of vitamin E is α -TOH, which is preferentially absorbed and retained in the body since the liver differentiates the forms of vitamin E and excretes α -TOH into the plasma. Vitamin E is an antioxidant that plays an important role in cellular respiration. Vitamin E is present in foods that contain fat and can be stored in the fatty tissues of animals and humans. Since it is fat-soluble, vitamin E does not need to be consumed every day. Among foods, the best source of vitamin E is vegetable oil. It is also found in various other foods such as nuts and seeds that contain high amounts of α -TOH, and significant amounts are also available in green leafy vegetables and fortified cereals (Arnarson, 2023).

Vitamin E, especially α -TOH, was studied because of its anti-bacterial, anti-inflammatory, and anti-cancer activity (Gupta et al., 2016; Gamna et al., 2021). So far, α -TOH has been detected and quantified with different techniques: spectroscopic techniques (Raman (RAMAN) spectroscopy, fourier-transformed infrared spectroscopy (FTIR), ultraviolet-visible (UV/Vis) spectrophotometry), high-performance liquid chromatography (HPLC) and spectrophotometric methods (2,2-Diphenyl-1-picrylhydrazyl (DPPH), Folin-Ciocalteu etc.) (Lee et al., 2004; Sawicki et al., 2020; Lampen et al., 2003; Orsavová et al, 2019; Marcos et al., 2014; Korchazhkina et al, 2006; Webster, 2022). Normal phase and reversed-phase HPLC were used to determine α -TOH in olive oil (Bakre et al., 2015), and FTIR- attenuated total reflectance (ATR) was also used to detect and quantify α -TOH in vegetable oils (Silva et al., 2009). Oxidation products of vitamin E hydrolysis and oxidation were also monitored using spectroscopic methods (UV-Vis, Raman, FTIR, electron paramagnetic resonance (EPR)) and voltammetry, and they were combined with fast photoinitiated excitation and time-resolved spectroscopy for the detection of short-lived species (Webster, 2022).

Until now, the electrochemical properties of α -TOH have not been extensively studied, so the main goal of our research was to characterize α -TOH using cyclic voltammetry (CV) and differential pulse voltammetry (DPV), and to detect α -TOH with HPLC in real samples (parsley, kale, and a powdered dietary supplement).

2. Materials and methods

Electrochemical measurements

All commercially available chemicals were of reagent grade and were used as purchased. Lithium chloride (LiCl) was purchased from VWR chemicals, ethanol absolute, p.a. was purchased from Gram-mol and α-tocopherol (purity 99,9%) was purchased from Sigma Aldrich). CV and DPV were used to test the electrochemical properties and oxidation mechanism of α -TOH. Electrochemical measurements were performed at room temperature ( θ= 25 ± 1 °C) in a three-electrode voltammetric cell connected to a PalmSens potentiostat/galvanostat (PalmSens BV, Utrecht, The Netherlands) equipped with PSTrace 4.2 software. The working electrode was a glassy carbon electrode area, A = 0.07 cm2) and it was polished before each measurement with α−Al2O3 (0.05 µm, Als, Japan). Ag/AgCl electrode for non-aqueous media was used as a reference electrode, while a platinum wire was used as the counter electrode. Electrochemical measurements were performed in a 15 mL cell and before each experiment, the system was purged with Ar5 ( φAr = 99.999%). Stock solution of α-tocopherol ( c = 1 mol/dm3) was prepared in Milli Q-Water (MQ H2O) and then the appropriate volume of stock solution was diluted with the appropriate solvent (mixture of ethanol and MQ H2O in 30:70 volume ratio) to the desired concentration before each measurement. Cyclic voltammograms were recorded in a potential range from -0.4 V to 1.0 V in a blank solution and a solution of α -TOH and the scan rate varied from 50 mV/s to 300 mV/s. Parameters used for differential pulse voltammetry were: scan rate of 5 mV/s, scan increment of 5 mV, pulse width of 70 ms, and pulse amplitude of 25 mV. All the potentials in this work are referred to as Ag/AgCl reference electrodes.

HPLC analysis

Samples

Dry parsley, dry kale, and a powdered dietary supplement were used as real samples. Parsley was bought dried, kale was fresh and then dried for 24 hours at 50 °C. Parsley and kale were ground in a home use mill and then sieved. A powdered dietary supplement was used without previous treatments. All samples were purchased from a local store. Real samples were stable for several days, so that the samples could be prepared a few days prior to analysis.

Calibration curve

The calibration curve was constructed in a range of concentrations from 5 to 60 mg/dm3. All standard solutions were prepared by diluting a 100 mg/dm3 stock solution with methanol. Stock solution was prepared from standard α -TOH (purity 99,9% Sigma Aldrich). All prepared standard solutions were kept at 4˚C.

For the measurement of α -TOH concentration, HPLC system Nexera X2 (Shimadzu) with a UV/Vis detector was used coupled with a Shim-pack GIST C-18 (150 mm x 4.6 mm, 5 µm) (Shimadzu) column, used for the separation. The mobile phase consisted of methanol (J. T. Baker, Poland) and isopropanol (Fisher Chemical, UK) (methanol: isopropanol = 45:55, V/V), flow rate - 0.7 mL/min, sample injection volume was 20 μL, and total analysis time for one sample was 10 min. All measurements were performed at 295 nm and at room temperature.

Extraction procedure

The extraction of α -TOH was carried out using methanol (Chen et al., 2005). The extraction mixture consisted of methanol and a 0.2% methanolic solution of BHT (2,6-Di-tert-butyl-4-methylphenol) (Acros Organics, Germany).

Analysis of real samples

Real samples were prepared by adding ground, sieved, and then weighed samples to amber tubes along with methanol (MetOH) and BHT. Sample: extraction mixture ratio for parsley and kale was 1:50 and for a dietary powdered supplement 1:1.25. The samples were vortexed for 1 minute and left in the dark for 1 hour. After 1 hour, the samples were centrifuged at 6000 rpm for 10 minutes and filtered with a syringe filter (pore size - 0.20 µm). The prepared samples were analyzed by means of HPLC with a previously used method (Martino et al., 2014).

Stability of real samples

The stability of parsley and kale was tested on three different samples with an extraction mixture ratio: of 1:30, 1:40, 1:50 for parsley, and 1:50, 1:80 and 1:100 for kale. Concentration of α-tocopherol was measured after 1 hour and after 96 hours for parsley and after 72 hours for kale. During waiting times of 96 hours and 72 hours, the samples were kept at 4 °C in the dark.

3. Results and discussion

CV and DPV

In order to find the optimal medium to study the electrochemical properties of α -TOH, cyclic (Fig. 1a) and differential pulse (Fig. 1b) voltammograms were recorded in pure ethanol and in mixtures of ethanol and water in a 50:50, 70:30 and 80:20 volume ratio. Both methods have shown that the most pronounced anodic peak current of α -TOH was present in an ethanol-aqueous mixture of 70:30 volume ratio, so all the experiments were performed in this medium.

image1.png

Figure 1. a) Cyclic voltammograms and b) differential pulse voltammograms of (▬) a blank solution and α -TOH ( c = 5x10-4 mol/dm3, Ic = 0.01 mol/dm3 LiCl) recorded in: (▬) ethanol and a mixture of ethanol and water in a (▬) 50:50, (▬) 70:30 and (▬) 80:20 volume ratio.

In the cyclic voltammogram recorded in a mixture of ethanol and water in a 70:30 volume ratio (Fig. 2), one oxidation peak of α -TOH was detected at the potential Ep, a = 0.175 V, which corresponds to the irreversible oxidation of α -TOH. In the oxidation of α -TOH, one electron is exchanged and the cation radical ( α -TOH+·) is formed. The cation radical rapidly deprotonates into the neutral phenoxyl radical ( α -TO·), which further oxidizes at the electrode surface to form a diamagnetic cation ( α -TO+) (Webster, 2022).

image2.png

Figure 2. Cyclic voltammograms of: (▬) α -TOH ( c = 5x10-4 mol/dm3, Ic = 0.01 mol/dm3 LiCl) and (▬) a blank solution-mixture of ethanol and water in a 70:30 volume ratio.

In Fig. 3a, cyclic voltammograms of α -TOH recorded on the glassy carbon electrode at different scan rates ( ν = 50-300 mV/s) are shown. It can be seen that the oxidation peak current and the oxidation peak potential increase with the increase of a scan rate. The logarithm of anodic peak current ( Ip, a) is a linear function of the logarithm of a scan rate (log ν ) (Fig. 3b) with a slope around 0.5, which indicates that the oxidation of α -TOH is a diffusion-controlled process (David et al., 2018).

image3.png

Figure 3. a) Cyclic voltammograms of (▬) a blank solution and α -TOH ( c = 5x10-4 mol/dm3, Ic = 0.01 mol/dm3 LiCl) at the scan rate, ν = (▬) 50, (▬) 100, (▬) 150, (▬) 200, (▬) 250 and (▬) 300 mV/s. b) the logarithm of oxidation peak current (log Ip, a) as a function of the logarithm of scan rate (log ν ).

DPV was also used to study the electrochemical properties of  α -TOH. In a differential pulse voltammogram (Fig. 4a), one anodic peak current was detected at the potential, Ep, a = 0.070 V, which also corresponds to the oxidation of α -TOH (Shu-Guo et al., 2008). The oxidation peak current ( Ip, a) increases with the increase of α -TOH mass concentration (Fig. 4b). Linear correlation of Ip, a vs α -TOH mass concentration ( γ) was obtained with the equation: Ip, a (μA) = 0.0126 γ / (mg/dm3) + 0.0358 ( R2= 0.9912) in the concentration range from 0.43 mg/dm3 to 70.41 mg/dm3.

image4.png

Figure 4. a) Differential pulse voltammograms of: (▬) α -TOH( c = 5x10-4 mol/dm3, Ic = 0.01 mol/dm3 LiCl) and (▬) a blank solution and b) differential pulse voltammograms of α -TOH at different mass concentrations, γ = (▬) 0.43, (▬ ) 1.10, (▬) 3.09, (▬) 5.07, (▬) 9.02, (▬) 40.69 and (▬) 70.41 mg/dm3. Inset: Anodic peak current ( Ip,a) as a function of mass concentration ( γ) of α -TOH.

HPLC

Calibration curve

Chromatograms obtained by measuring series of standard solutions of α -TOH are shown in Fig. 5a. The calibration curve constructed using the Lab Solutions software is shown in Fig. 5b. The value of the coefficient of determination was R2 = 0.9992 and we can conclude that the measured values and the regression line correlate.

image5.png

Figure 5. a) Comparison of chromatograms obtained by measuring the absorbance of a series of standard α -TOH solutions (▬ 5 mg/dm3, ▬ 10 mg/dm3, ▬ 20 mg/dm3, ▬ 60 mg/dm3) and b) calibration curve of α -TOH.

Analysis of real samples

Results of the HPLC analysis of real samples are shown in Table 1. Parsley had the highest concentration of α -TOH 8.267 mg/kg, while kale had a significantly lower concentration of 1.492 mg/kg. The lowest concentration was measured in a powdered dietary supplement which amounted to 0.067 mg/kg. The determined concentration of α -TOH in the powdered dietary supplement was not in accordance with the supplement declaration. The resulting discrepancy could be explained by the complex composition of the supplement, which contains additional substances that interfere with the extraction and analysis of the sample itself.

Table 1. Concentration of α -TOH in real samples obtained by HPLC analysis.

SampleparsleykalePowdered dietary supplement
Sample: extraction mixture ratio1:501:501:1.25
γ ( α -TOH) / mg/kg
18.4001.4500.056
28.3001.5250.066
38.1001.5000.078
Average8.2671.4920.067
SD0.1530.0380.011
RSD (%)1.8482.56015.947
Confidence (±)0.1220.0310.009

Stability of real samples

The stability of parsley and kale samples is shown in Tables 2 and 3. As can be seen from the Tables 2 and 3, the decrease in the concentration of α -TOH in parsley was not higher than 1.72% after 96 hours, and the concentration of α -TOH in kale after 72 hours increased by 4% in the sample with an extraction mixture ratio of 1:50, and for the sample with an extraction mixture ratio of 1:80, the concentration decreased by 6.6%, but for the sample with a solvent ratio of 1:100, the concentration of α -TOH did not change.

Table 2. Results of the stability test for parsley for different samples: extraction mixture ratio and two extraction times.

Extraction time1 h96 h
Sample: extraction mixture ratio γ (α -TOH ) / mg/kg
parsley1:306.9396.848
parsley1:406.9606.840
parsley1:506.9506.850

Table 3. Results of the stability test for kale for different samples: extraction mixture ratio and two extraction times.

Extraction time1 h72 h
Sample: extraction mixture ratio
kale1:501.2501.300
kale1:801.2001.120
kale1:1001.1001.100

4. Conclusion

In this study, CV and DPV were used for the electrochemical characterization of α -TOH in an ethanol-aqueous mixture in a 70:30 volume ratio. Cyclic and differential pulse voltammograms have shown one oxidation peak which corresponds to the oxidation of α -TOH. In the oxidation of α -TOH, rapid two-electron oxidation, coupled with one proton loss (–2e/–1H+) occurred, and a diamagnetic cation ( α -TO+) was formed. Oxidation of α -TOH is an irreversible and a diffusion-controlled process since the linear correlation between anodic peak current, Ip, a, and the square root of scan rate ( ν )1/2 was observed. It was also determined that the anodic peak current of α -TOH increases with the increase of its concentration (linear response was obtained in the concentration range from 0.43 mg/dm3 to 70.41 mg/dm3). The obtained values of α -TOH in real samples with HPLC were 8.267 mg/kg for parsley, 1.492 mg/kg for kale, and 0.067 mg/kg for powdered dietary supplement.

Author Contributions: D. G.: formal analysis, writing-original manuscript draft preparation, review, and editing. V. D. performed the HPLC and voltammetric measurements, data collection, formal analysis. O. G.: conceptualized the project, analyzed the experimental data, writing - original manuscript draft preparation. M. M.-K.: project conceptualization, supervision, review, and editing. All authors read and approved the final manuscript.

Funding: This research was funded by the European Structural and Investment Funds grant for the Croatian National Scientific Center of Excellence for Personalized Health Care, Josip Juraj Strossmayer University of Osijek (grant #KK.01.1.1.01.0010).

Conflicts of Interest: The authors declare no conflict of interest.

References

 

Arnarson, A., Healthline resources on the Web. 202320 Foods That Are High in Vitamin E. https://www.healthline.com/nutrition/foods-high-in-vitamin-eAccessed October 19, 2023.

 

Bakre, S.M., Gadmale, D.K., Toche, R.B., Gaikwad, V.B. 2015Rapid determination of alpha-tocopherol in olive oil adulterated with sunflower oil by reversed-phase high-performance liquid chromatography. Journal of Food Science and Technology. 52:53093–53098. https://doi.org/10.1007/s13197-014-1309-7

 

Chen, M.H., Bergman, C.J. 2005A rapid procedure for analysing rice bran tocopherol, tocotrienol and α-oryzanol contents. Journal of Food Composition and Analysis. 18:139–151. https://doi.org/10.1016/j.jfca.2003.09.004

 

David, I.G., Litescu, S.C., Popa., D.E., Buleandra, M., Iordache, L., Albu, C., Alecu, A., Penu, R.L. 2018Voltammetric analysis of naringenin at a disposable pencil graphite electrode – application to polyphenol content determination in citrus juice. Analytical Methods. 10(48):5763–5772. https://doi.org/10.1039/C8AY02281J

 

Gamna, F., Spriano, S. 2021Vitamin E: A Review of Its Application and Methods of Detection When Combined with Implant Biomaterials. Materials. 14(13):3691https://doi.org/10.3390/ma14133691

 

Gupta, S.D., Suh, N. 2016Tocopherols in cancer: an update. Molecular Nutrition & Food Research. 60(6):1354–1363. https://doi.org/10.1002/mnfr.201500847

 

Korchazhkina, O., Jones, E., Czauderna, M., Spencer, S.A., Kowalczyk, J. 2006HPLC with UV detection for measurement of vitamin E in human milk. Acta Chromatographica. 16:48–57

 

Lampen, P., Pittermann, W., Heise, H.M., Schmitt, M., Jungmann, H., Kietzmann, M. 2003Penetration studies of vitamin E acetate applied from cosmetic formulations to the stratum corneum of an in vitro model using quantification by tape stripping, UV spectroscopy, and HPLC. Journal of Cosmetic Science. 54:119–131

 

Lee, C.H., An, D.S., Lee S.C., Park, H.J., Lee, D.S.: 2004A coating for use as an antimicrobial and antioxidative packaging material incorporating nisin and α-tocopherol. Journal of Food Engineering. 62(4):323–329. https://doi.org/10.1016/S0260-8774(03)00246-2

 

Marcos B., Sárraga, C., Castellari, M., Kappen, F., Schennink, G., Arnau, J. 2014Development of biodegradable films with antioxidant properties based on polyesters containing α-tocopherol and olive leaf extract for food packaging applications. Food Packaging and Shelf Life. 1(2):140–150. https://doi.org/10.1016/j.fpsl.2014.04.002

 

Martino, G., Naceur Haouet, M., Marchetti, S., Grotta, L., Ponzielli, V. 2014Effect of Vitamin E Supplementation on Egg Yolk Quality and Oxidative Stability. Asian Journal of Agriculture and Food Sciences. 4:248–255

 

Orsavová, J., Hlaváčová, I., Mlček, J., Snopek, L., Mišurcová, L. 2019Contribution of phenolic compounds, ascorbic acid and vitamin E to antioxidant activity of currant (Ribes L.) and gooseberry (Ribes uva-crispa L.) fruits. Food Chemistry. 30(284):323–333. https://doi.org/10.1016/j.foodchem.2019.01.072

 

Sawicki, T., Bączek, N., Starowicz, M. 2020Characterisation of the total phenolic, vitamins C and E content and antioxidant properties of the beebread and honey from the same batch. Czech Journal of Food Sciences. 38(3):158–163. https://doi.org/10.17221/312/2019-CJFS

 

Schneider C. 2005Chemistry and biology of vitamin E. Molecular Nutrition & Food Research. 49(1):7–30. https://doi.org/10.1002/mnfr.200400049

 

Shu-Guo, L., Hui, C., Xue-Mei, L., Wen-Tong, Hui, Z. 2008Determination of Vitamin E in Vegetable Oils by Differential Pulse Voltammetry. Journal of Food Science. 29(3):369–373

 

Silva, S.D., Rosa, N.F., Ferreira, A.E., Boas, L.V., Bronze, M.R.: 2009Rapid determination of α -tocopherol in vegetable oils by Fourier transform infrared spectroscopy. Food Analytical Methods. 2:120–127. https://doi.org/10.1007/s12161-008-9047-y

 

Webster, R.D. 2022Electrochemical and Spectroscopic Characterization of Oxidized Intermediate Forms of Vitamin E. Molecules. 27(19):6194https://doi.org/10.3390/molecules27196194


This display is generated from NISO JATS XML with jats-html.xsl. The XSLT engine is libxslt.