Skip to the main content

Professional paper

Comparison of two methods for lactose determination in whey

Matilda Grüner ; Prehrambeno-biotehnološki fakultet, Pierottijeva 6, 10000 Zagreb
M. Filajdić
D. Hanser


Full text: croatian pdf 711 Kb

page 49-54

downloads: 520

cite


Abstract

In this article gravimetric (A) and enzymatic (B) methods for lactose determination have been compared in 7 samples of whey and two repetitions. The statistical difference between these two methods was established by analysis of variance. As relatively few laboratories in our milk factories use enzymatic method, this article describes calculation procedure which would make possible to convert the results obtained by gravimetric method into those which would be expected using enzymatic one. The calculation by matrices algebra in linear and quadratic models has generated as follows: Y(1) = -0,2754 + 1,0736 (xi) (1); Y(2) = 2,4613 - 0,2975(Xi) + 0,1705(xi)^2 (2), where: xi = mass fractions (g/100 g) of lactose determined by gravimetric method, Y(1) and Y(2) are calculated results which would be expected if using enzymatic method.

Keywords

lactose determination; methods - gravimetric, enzymatic; calculative results' convert

Hrčak ID:

95359

URI

https://hrcak.srce.hr/95359

Publication date:

17.1.1993.

Article data in other languages: croatian

Visits: 1.287 *