Skip to the main content

Conference paper

https://doi.org/10.15255/KUI.2026.034

CFD Modelling of a Double-Pipe Heat Exchanger

Matea Čulina ; University of Split, Faculty of Chemistry and Technology, Ruđera Boškovića 35, 21 000 Split, Croatia
Marija Ćosić ; University of Split, Faculty of Chemistry and Technology, Ruđera Boškovića 35, 21 000 Split, Croatia
Željko Penga ; University of Split, Faculty of Electrical Engineering, Mechanical Engineering and Naval Architecture, Ruđera Boškovića 32, 21 000 Split, Croatia
Antonija Čelan ; University of Split, Faculty of Chemistry and Technology, Ruđera Boškovića 35, 21 000 Split, Croatia *

* Corresponding author.


Full text: english pdf 1.503 Kb

page 777-787

downloads: 0

cite


Abstract

This study examines the thermal and hydrodynamic behaviour of a 1.5 m laboratory-scale counter-current double-pipe heat exchanger, under selected operating conditions, using both experimental measurements and computational fluid dynamics (CFD). The main objective was to demonstrate a detailed procedure for CFD model development, including geometry preparation, mesh generation, near-wall treatment, and to assess how turbulence model selection and wall treatment affect the accuracy of numerical predictions. A three-dimensional CFD model was created in ANSYS Fluent 2024 R1. Particular attention was given to segmenting the geometry and generating a structured hexahedral mesh to ensure high mesh quality and compliance with the near-wall requirements of the turbulence models used. Two mesh configurations were developed: one for k-ε-based models with dimensionless wall distance (y⁺) values between 30 and 40, and a refined mesh for the SST k-ω model with y⁺ values between 1 and 5. The standard k-ε, realisable k-ε, and SST k-ω models were tested, with both standard and enhanced wall treatments applied to the k-ε based models. Predicted outlet temperatures showed good agreement with experimental results, with deviations ranging from 1 to 11 %, depending on the model. The SST k-ω model produced the most accurate outlet temperature predictions, with deviations below 1.5 % for both fluid streams. Pressure-drop values also closely matched those calculated using the Darcy-Weisbach equation. Overall, the study presents a complete, step-by-step development of the CFD model and demonstrates that the SST k-ω turbulence model achieves the best overall accuracy, although at the cost of significantly longer simulation times.

Keywords

double-pipe heat exchanger; CFD; mesh; turbulence models; temperature; pressure drop; velocity

Hrčak ID:

353578

URI

https://hrcak.srce.hr/353578

Publication date:

21.11.2026.

Article data in other languages: croatian

Visits: 0 *